Xantrex C35 Charge Controller 35A, 12 or 24V
C35 Charge Controller, 35A,12 or 24V
Features
As a Solar Charge Controller
As a DC Load Controller
As a Diversion Load Controller
Options
Also Known As:
C35.DISC
C35 DISC
C35_DISC
C35DISC
Electrical Specifications | |
Voltage Configurations | 12, 24 and 48 VDC |
Max. PV Open Circuit Array Voltage | 125 VDC |
Charging / Load Current (at 25 °C) | 40 amps DC |
Max. Peak current | 85 amps |
Max. Voltage Drop through Controller | 0.30 volts |
Typical Operating Consumption | 15 ma |
Typical Idle Consumption | 3 ma |
Recommended Breaker Size | 50 amps |
Recommended Wire Size | #8 AWG |
Lead AcidBatterySettings | Adjustable |
NiCadBatterySettings | Adjustable |
Load Control Mode | Low Voltage Reconnect - Adjustable (sticker provided with unit) all models |
Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models | |
General Specifications | |
SpecifiedTemperatureRange | 32° F to 104° F (0° C to 40° C) |
Enclosure Type | Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts |
Unit Weight | 3.0 lb (1.4 kg) |
Shipping Weight | 3.5 lb (1.6 kg) |
Dimensions (H x W x D) | 10 x 5 x 2.5" (25.4 x 12.7 x 6.35 cm) |
Shipping Dimensions (H x W x D) | 12.4 x 7 x 2.5" (31.5 x 17.8 x 6.4 cm) |
Mounting | Vertical wall mount - indoor only |
Altitude - Operating | 15,000' (4,572 m) |
Altitude - Non-Operating | 50,000' (15,240 m) |
Warranty | Two years |
Part Numbers | C35, C40, C60 - Controllers |
CM/R-50 - Remote Display Panel | |
BTS -Batterytemperature sensor | |
Features & Options | |
Regulation Method | Solid stage, three-stage (bulk, absorption, and float), pulse width modulation |
Field Adjustable Control Setpoints | Two user adjustable voltage setpoints for control of loads or charging sources - setting retained if battery is disconnected |
Display Panel | CM/R-50 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50' (15 m) or 100' (30.5 m) cable |
Equalization Charge | User selectable manual or automatic equalization - every 30 days |
BatteryTemperature Sensor | BTS - optional remote battery temperature sensor for increased charging precision |
Regulatory Approvals | UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant |