SolarEdge SE3800A-US 3.8 KW Single Phase Grid Tied Inverter
SE3800A-US 3.8 KW Single Phase Grid Tied Inverter
All our inverters are part of SolarEdge’s innovative system designed to provide superior performance at a competitive price. The SolarEdge inverter combines a sophisticated, digital control technology and a one stage, ultra-efficient power conversion architecture to achieve superior performance – over 97% efficiency and best-in-class reliability. Our fixedvoltage technology ensures the inverter is always working at its optimal input voltage, regardless of the number of modules or environmental conditions.
These simple, reliable, ungrounded inverters perform only DC to AC inversion of incoming power from one or multiple strings, because MPPT and voltage management are handled by the power optimizers. They work with 208, 240, and 277 VAC systems, and include a code-compliant AC/DC disconnect, On board Ethernet interface, and RS-485 serial port, weigh 48 pounds and reach 97.5% CEC weighted efficiency. All SolarEdge inverters are listed to UL 1741 for the U.S. and Canada and are NEMA 3R rated.
Features of the SolarEdge SE3800A-US 3.8 KW Single Phase Grid Tied Inverter:
Also Known As:
SE38000A.US
SE38000A US
SE38000A_US
SE38000AUS
Specification SolarEdge Single Phase Inverter | SE3000A-US | SE3800A-US | SE5000A-US | SE6000A-US |
Output | ||||
Rated AC Power Output | 3000 W | 3800 W | 5000 W | 6000 W |
Maximum AC Power Output | 3000 W | 4150 W | 5000W | 6000 W |
AC Output Voltage Minimum-Nominal-Maximum | 183 - 208 - 229 / 211 - 240 - 264 Vac | 183 - 208 - 229 / 211 - 240 - 264 / 244 - 277 - 294 Vac | ||
AC Frequency (Nominal) | 59.3 - 60 - 60.5 Hz | |||
Maximum Continuous Output Current | 12.5 A | 16 A | 24 @208V 21 @ 240V | 25 A |
GFDI | 1 A | |||
Utility Monitoring, Islanding Protection, Country Configurable Thresholds | Yes | |||
Input | ||||
Recommended Maximum DC Power (Module STC) | 3750 W | 4750 W | 6250 W | 7500 W |
Transformer-less, Ungrounded | Yes | |||
Maximum Input Voltage | 500 Vdc | |||
Nominal DC Input Voltage | 325 @ 208V / 350 @ 240V | |||
Maximum Input Current | 9.5 Adc | 13Adc | 16.5 Adc @ 208V 15.5 Adc @ 240V | 18 Adc |
Reverse-Polarity Protection | Yes | |||
Ground-Fault Isolation Detection | 600 k Sensitivity | |||
Maximum Inverter Efficiency | 97.5% | 98.2% | 98.3% | 98.3% |
CEC Weighted Efficiency | 97.5 % | 98% | 97.5% @ 208V 98% @ 240V | 97% @ 208V / 97.5% @ 240V/ 98% @ 277V |
Nighttime Power Consumption | < 2.5 W | |||
Additional Features | ||||
Supported Communication Interfaces | RS485, RS232, Ethernet, Zigbee (optional) | |||
Revenue Grade Data, ANSI C12.1 | Optional | |||
Standard Compliance | ||||
Safety | UL1741, UL1699B, UL1998 , CSA 22.2 | |||
Grid Connection Standards | IEEE1547 | |||
Emissions | FCC part15 class B | |||
Installation Specifications | ||||
AC Output Conduit Size/ AWG range | 3/4" minimum / 24-6 AWG | |||
DC Input Conduit Size/ # of string/ AWG range | 3/4" minimum / 1.2 strings / 24-6 AWG | |||
Dimensions (HxWxD) | 30 x 12.5 x 7 in 775 x 315 x 172 mm | 21 x 12.5 x 7.5 in 540 x 315 x 191 mm | ||
Weight with AC/DC Safety Switch | 51.2 lbs / 23.2 kg | 54.7 lbs / 24.7 kg | ||
Cooling | Natural Convection | |||
Operating Temperature Range | -13° to +140°F / -20° to +60°C | |||
Noise | < 25 dBA | |||
Protection Rating | NEMA 3R |