SMA SI-TD-BOX Smartformer 120/240V Transformer Distribution Box
SI-TD-BOX Smartformer 120/240V Transformer Distribution Box
The Smartformer is the complete solution for off-grid and battery back-up systems up to eight kilowatts. It acts simultaneously as AC distribution and a 120 V/240 V autoformer. The autoformer provides step-up and step-down options to supply loads with 120 V and 240 V using a Sunny Island and a Sunny Boy, with high efficiency over the entire power spectrum. Thanks to the pre-wired bypass function, the PV system can be easily bridged via a robust switch for maintenance. The optimized transformer overload protection and a load shedding relay provide extra protection to the system. The Smartformer makes the stand-alone power supply simple and reliable.
Features of the SMA SI-TD-BOX Smartformer 120/240V Transformer Distribution Box:
Simple
Complete
Efficient
Safe
Also Known As:
SI.TD.BOX
SI TD BOX
SI_TD_BOX
SITDBOX
Technical Data | SI-TD-BOXSmartformer |
General data | |
Number of phases | Split-phase |
Rated voltage | 120 Vac/240 Vac |
AC voltage range between L1 and N | 102 V - 132 V |
AC voltage range between L1 and L2 | 204 V - 264 V |
Rated frequency | 60 Hz |
Dimensions (width x height x depth) | 24.02 x 24.02 x 9.25 in (610 x 610 x 235 mm) |
Weight | approx. 123.5 lbs (approx. 56 kg) |
Idle power consumption | 19 W (typical) |
Rated power transformer | 3.4 kVA |
Max. efficiency/CEC efficiency | 99% / 98.8% |
Transformer AC power for 30 min | 4.4 kVA |
Transformer AC power for 1 min | 8.8 kVA |
Conduit access | Knockouts top: 2x 3/4”, 2x 1”, 2x 1 1/4” bottom: 5x 3/4”, 3x 1”, 3x 1 1/4” |
Connections for Sunny Island | |
Maximum number and nominal voltage of Sunny Island | 1 x 120 V (L1, N) |
Rated power | 5.8 kW |
Current at rated values | 48 A |
Fuses | 1 |
PV plant connection | |
Number of connections/nominal voltage | 1 x 240 V (L1, L2, N) |
Rated power | 9.6 kW |
AC power in parallel grid operation | 6 kW |
AC current at rated values | 40 A |
Fuses | 2 |
Load connection | |
Number of connections/rated voltage | 1 x 120 V/240 V |
Rated power | 7.2 kW |
AC power at 40 °C | 6.6 kW |
Rated power / current between L₁ and L₂ | 6.7 kW / 28 A |
Rated power / current between L₁ and N | 3.8 kW / 32 A |
Rated power / current between L₂ and N | 3.4 kW / 28 A |
Current at rated values | 32 A, 28 A (with activated bypass: 2 x 48 A) |
Fuse | K40A (with activated bypass: K60A) |
PV array connection | |
Number of connections/rated voltage | 120 V / 240 V (L1, L2, N) |
Rated grid input power | 11.5 kW |
AC input current | 48 A |
Fuse | 2 |
Ambient conditions | |
Operating temperature range | -13 °F ... +140 °F (-25 °C ... +60 °C) |
Humidity | 0 - 100% (non-condensing) |
Protection class | NEMA Type 1 |
Certification and approval | UL 1741 |
Features/function | |
Warranty: 5/10/15/20 years | yes/opt./opt./opt. |
Integrated bypass for maintenance/load shedding relay/transformer protection | yes/yes/yes |
Type designation | SI-TD-BOX-10 |