SMA SB 8000US-12 Sunny Boy 8000W Grid Tie Inverter with AFCI
SB 8000US-12 Sunny Boy 8000W Grid Tie Inverter with AFCI
Maximal energy yields for a continuously expanding solar market: the Sunny Boys with US certification are impressive due to their excellent efficiency. Additionally, they offer the highest degree of flexibility in plant design due to their graduated performance classes. The automatic grid voltage detection* allows easy and safe installation. Furthermore, the galvanic isolation provides flexible connection possibilities. This way, the Sunny Boy inverters can be used with crystalline cells, as well as with thin-film modules.
Features of the SMA SB 8000US-12 Sunny Boy 8000W Grid Tie Inverter with AFCI:
Certifications
Efficient
Safe
Simple
Also Known As:
SB.8000US-12
SB-8000US-12
SB_8000US-12
SB8000US-12
Also Known As:
SB.8000US-12
SB-8000US-12
SB_8000US-12
SB8000US-12
Technical Data | Sunny Boy SB 5000-US | Sunny Boy SB 6000-US | Sunny Boy SB 7000-US | Sunny Boy SB 8000-US |
208 Vac 240 Vac 277 Vac | 208 Vac 240 Vac 277 Vac | 208 Vac 240 Vac 277 Vac | 240 Vac 277 Vac | |
Input (DC) | ||||
Recommended Maximum PV Power (Module STC) | 6250 W | 7500 W | 8750 W | 10000 W |
Max. DC Power | 5300 W | 6350 W | 7400 W | 8600 W |
DC Maximum Voltage | 600 V | 600 V | 600 V | 600 V |
DC Nominal Voltage | 310 V | 310 V | 310 V | 345 V |
MPP Voltage Range | 250—480 V | 250—480 V | 250—480 V | 300—480 V |
Min DC Voltage/Start Voltage | 250 V / 300 V | 250 V / 300 V | 250 V / 300 V | 300 V / 365 V |
Max. input current / per string (at DC disconnector) | 21 A/20A 36A @ combined terminal | 25 A/20A 36A @ combined terminal | 30 A/20A 36A @ combined terminal | 30 A/20A 36A @ combined terminal |
Number of MPP trackers/ fused-protected strings per MPP tracker | 1 / 4 (DC disconnect) | |||
Output (AC) | ||||
AC Nominal Power | 5000 W | 6000 W | 7000 W | 7680 @ 240 V 8000 W @ 277 V |
AC Maximum Output Power | 5000 VA | 6000 VA | 7000 VA | 7680 @ 240 VA 8000 W @ 277 VA |
Nominal AC voltage / adjustable | 208 V / ● 240 V / ● 277 V / ● | 240 V / ● 277 V / ● | ||
AC Voltage Range | 183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V | 211 — 264 V @ 240 V 244 — 305 V @ 277 V | ||
AC Grid Frequency; range | 60 Hz / 59.3 — 60.5 Hz | |||
Maximum Output Current | 24 A @ 208 V 21 A @ 240 V 18 A @ 277 V | 29 A @ 208 V 25 A @ 240 V 22 A @ 277 V | 34 A @ 208 V 29 A @ 240 V 25 A @ 277 V | 32 A @ 240 V 29 A @ 277 V |
Power Factor (Nominal) | 1 | |||
Phase conductors / connection phases | 1 / 2 @ 208 V 1 / 2 @ 240 V 1 / 1 @ 277 V | 1 / 2 @ 240 V 1 / 1 @ 277 V | ||
Harmonics | < 4 % | |||
Efficiency | ||||
Max Efficiency | 96.7% @ 208 V 96.8% @ 240 V 96.8% @ 277 V | 96.9% @ 208 V 96.8% @ 240 V 97.0% @ 277 V | 97.1% @ 208 V 96.9% @ 240 V 97.0% @ 277 V | 96.3% @ 240 V 96.5% @ 277 V |
CEC Weighted Efficiency | 95.5% @ 208 V 95.5% @ 240 V 95.5% @ 277 V | 95.5% @ 208 V 95.5% @ 240 V 96.0% @ 277 V | 95.5% @ 208 V 96.0% @ 240 V 96.0% @ 277 V | 96.0% @ 240 V 96.0% @ 277 V |
Protection devices | ||||
DC reverse-polarity protection | Standard | |||
Integrated AFCI | Standard | |||
AC short circuit protection | Standard | |||
Galvanically isolated / all-pole sensitive monitoring unit | Standard / NA | |||
Protection class / overvoltage category | I/III | |||
General Data | ||||
Dimensions: (W / H / D) in inches | 18.5 x 24 x 9 in. (470 x 615 x 240 mm) | |||
DC Disconnect dimensions (W / H / D) in inches | 7 x 12 x 7.5 in. (187 x 297 x 190 mm) | |||
Weight /DC Disconnect Weight | 148 lbs / 8 lbs | 152 lbs / 9 lbs | ||
Operating temperature range (full power) | -40 °C ... +45 °C / -40 °F ... +113 °F | |||
Noise emission (typical) | 44 dB(A) | 45 dB(A) | 46 dB(A) | 49 dB(A) |
Internal consumption: (night) | 0.1 W | |||
Topology | LF transformer | |||
Cooling Concept | OptiCool | |||
Electronics protection rating / connection area | NEMA 3R / NEMA 3R | |||
Features | ||||
Display: text line / graphic | yes /— | yes /— | yes /— | yes /— |
Interfaces: RS485 / Bluetooth | opt. / opt. | opt. / opt. | opt. / opt. | opt. / opt. |
Warranty: 10 years / 15 years / 20 years | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. |
Certificates and permits (more available on request) | UL1741 (Second Ed.), UL1998, UL1699B, IEEE 1547, FCC Part 15 (Class A & B), CSA C22.2 No. 107.1-2001 | |||
Type designation | SB 5000US-12 | SB 6000US-12 | SB 7000US-12 | SB 8000US-12 |