SMA SB 240-US-10 Sunny Boy 240W Micro Inverter
SB 240-US-10 Sunny Boy 240W Micro Inverter
SMA’s Sunny Boy micro inverter system enhances design flexibility for installers in the U.S. and across the globe. It features industry-leading 96% CEC efficiency, simple installation, an innovative communications platform and is especially applicable for residential systems and rooftops with complex, shaded situations. An improved cabling concept further elevates the Sunny Boy 240 from the competition by eliminating the need for a trunk cable.
Optimized Reliability
Simple Installation
Unrivaled Monitoring
SMA-Backed Security
Also Known As:
SB.240-US-10
SB-240-US-10
SB_240-US-10
SB240-US-10
Also Known As:
SB.240-US-10
SB-240-US-10
SB_240-US-10
SB240-US-10
Sunny Boy 240-US | Sunny Multigate-US | |
Input (DC) | ||
Max. DC power (@ cos φ = 1) | 250 W | N / A |
Max. number of micro inverters | N / A | |
Max. input voltage | 45 V | N / A |
MPP voltage range / rated input voltage | 23 V ...32 V / 29.5 V | N / A |
Min. input volatge / start voltage | 15 V / 23 V | N / A |
Max. input current | 8.5 A | N / A |
Max. input current per string | 8.5 A | N / A |
Number of independent MMP inputs / String per MPP input | 1 / 1 (Unfused) | N / A |
Output (AC) | ||
Rated power (@ 240 V. 60 Hz) | 240 W | N / A |
Max. apparent AC power | 240 VA | 2880 VA / 2880 W |
Nominal AC voltage / range | 2 x 120 V / 211 V - 264 V | 2 x 120 V / 211 V - 264 V |
AC power frequency / range | 60 Hz; 59.3 — 60.5 Hz | 60 Hz; 59.3 — 60.5 Hz |
Rated power frequency / rated grid voltage | 60 Hz / 240 V | 60 Hz / 240 V |
Max. ouput current | 1 A | 12 A |
Power factor at rated power | 1 | 1 |
Feed-in phases / connection phases | 2 / 2 X 120 V split phase | - / 2 X 120 V split phase |
Efficiency | ||
Max. efficiency | 95.9% | 99.9% |
CEC efficiency | 96% | N / A |
Protection devices | ||
Ground fault monitoring / grid monitoring | yes | N / A |
DC reverse polarity / AC short-circuit current capability / galvanically isolated | yes / yes / yes | N / A |
Grid monitoring / AC short-circuit current capability | N / A | N / A |
Max. permissible fuse protection | N / A | 15 A Circuit Breaker |
General Data | ||
Dimensions (W / H / D) | 188.4 / 218.4 / 43.7 mm (7.4 / 8.6 / 1.7 im) | 162 / 90 / 63 (6.4 / 3.5 / 2.5) |
Weight | 1.3 kg / 2.9 lbs | .07 kg / 1.5 lb |
Operating temperature range | —40 °C ... +65 °C (—40 °F ... +149 °F) | —40 °C ... +45 °C (—40 °F ... +113 °F) |
Topology | HF transformer | N / A |
Cooling concept | Convection | Convection |
Degree of protection (according to IEC 60529) | NEMA 3R | Type 1 |
Max. permissible value for relative humidity (non-condensing) | 100% | N / A |
Features | ||
DC Connection | Connector | N / A |
AC Connection | Connector | Screw terminal |
Interface: Webconnect | N / A | yes |
Certificates and permits (more available on request) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B), IEC 62109-1/-2 (CAN/CSA C22.2 No. 107.1-1) | |
Data at nominal conditions | ||
Type designation | SB 240-US-10 | Multigate-US-10 |