Schneider C40 Charge Controller 40A, 12/24/48V
C40 Charge Controller, 40A, 12/24/48V
As a Solar Charge Controller
As a DC Load Controller
As a Diversion Load Controller
Options
Electrical Specifications | C35 | C40 | C60 |
Rated PV current | 35 A | 40 A | 60 A |
Charging / load current @ 25°C (77°F) | 35 A | 40 A | 60 A |
Voltage configurations | 12 and 24 | 12, 24, and 48 | 12 and 24 |
Max. PV open circuit array voltage | 55 V | 125 V | 55 V |
Max. voltage drop through controller | 0.30 volts | ||
Total operating consumption | 15 mA | ||
Recommended NEC breaker size | 60 A rated at 100% continuous duty | ||
Recommended wire size | 50 amps | ||
Lead acid battery settings | Adjustable | ||
NiCd BatterySettings | Adjustable | ||
Load Control Mode | Low voltage reconnect – adjustable (sticker provided with unit) all models Low voltage disconnect – user selectable manual or automatic reconnection – (includes warning flash before disconnect and provides a one time, user selected grace period) all models | ||
General Specifications | |||
Power consumption, night time | 3 mA | ||
Enclosure material | Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts | ||
Product weight | 1.2 kg (2.7 lb) | 1.4 kg (3.1 lb) | 1.4 kg (3.1 lb) |
Shipping weight | 1.4 kg (3.1 lb) | 1.6 kg (3.5 lb) | 1.6 kg (3.5 lb) |
Dimensions (H x W x D) | 20.3 x 12.7 x 6.4 cm (8.0 x 5.0 x 2.5 in) | 25.4 x 12.7 x 6.4 cm | 25.4 x 12.7 x 6.4 cm (10.0 x 5.0 x 2.5 in) |
Shipping Dimensions (H x W x D) | 31.5 x 17.8 x 6.4 cm (12.4 x 7.0 x 2.5 in) | ||
Device mounting | Vertical wall mount - indoor only | ||
Ambient air temperature for operation | 0°C to 40°C (32°F to 104°F) | ||
Operating altitude | 4572 m (15000 ft) | ||
Non-operating altitude | 15240 m (50000 ft) | ||
Warranty | Two-year standard | ||
Features | |||
Display type | Multi color LED indicates the operating and battery voltage status | ||
Field Adjustable Control Setpoints | Solid state, three-stage (bulk, absorption, and float), pulse width modulation | ||
Display Panel | Two user adjustable voltage setpoints for control of loads or charging sources – settings retained if battery is disconnected | ||
Equalization Charge | User selectable manual or automatic equalization - every 30 days | ||
Options | |||
CM/R-50 | Backlit LCD remote, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, 30.5 m (100 ft) cable | ||
130-0004-02-01 | Battery temperature sensor for increased charging precision, 7.62 m (25 ft) cable | ||
Regulatory approval | |||
Safety | UL listed to UL1741* and CSA 107.1-01; CE Marked for the Low Voltage Directive | ||
EMC | FCC and Industry Canada Class B, CE Marked for the EMC Directive |