Power-One Uno-2.0-I-OUTD-S-US 2000W Aurora Inverter
Uno-2.0-I-OUTD-S-US 2000W Aurora Inverter
The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the Aurora range. A new-look inverter but packed with Power-One’s proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system. The smallest of Power-One’s outdoor range, these new products are the right size for the average rooftop installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. The high speed MPPT off ers real-time power tracking and improved energy harvesting. Despite the isolated operation, the UNO-2.0-I and UNO-2.5-I feature an efficiency of 96.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Features of the Power-One Uno-2.0-I-OUTD-S-US 2000W Aurora Inverter:
Also Known As:
UNO.2.0.I.OUTD.S.US
UNO 2.0 I OUTD S US
UNO_2.0_I_OUTD_S_US
UNO2.0IOUTDSUS
Technical Data | UNO-2.0-I-OUTD-US | UNO-2.5-I-OUTD-US | ||||
Nominal Output Power | 2000 W | 2500 W | ||||
Maximum Output Power | 2200 W** | 2750 W** | ||||
Rated Grid AC Voltage | 208 V | 240 V | 277 V | 208 V | 240 V | 277 V |
Number of Independent MPPT Channels | 1 | |||||
Maximum Usable Power for each Channel | 2300 W | 2900 W | ||||
Absolute Maximum Voltage (Vmax) | 520 V | 520 V | ||||
Start-Up Voltage (Vstart) | 200 V (adj. 120-350) | |||||
Full Power MMPT Voltage Range | 170-470 V | 205-470 V | ||||
Operating MMPT Voltage Range | 0.7xVstart - 520 V | |||||
Maximum Current (Idcmax) for both MPPT in Parallel | 12.5 A | 12.8 A | ||||
Maximum Short Circuit Current Limit | 15 A | 15 A | ||||
Number of Landing Terminal Per Channel | 2 Pairs | |||||
Array Wiring Termination | Terminal Block, Pressure Clamp, 20AWG-6AWG | |||||
Output Side (AC) | ||||||
Grid Connection Type | 1Ø/2W | Split-Ø/3W | 1Ø/2W | 1Ø/2W | Split-Ø/3W | 1Ø/2W |
Adjustable Voltage Range(Vmin-vmax) | 183-228V | 211-264V | 244-304V | 183-228V | 211-264V | 244-304V |
Grid Frequency | 60 Hz | |||||
Adjustable Grid Frequency Range | 57 - 60.5 Hz | |||||
Maximum Current | 10 A | 12 A | ||||
Power Factor | > 0.990 | |||||
Grid Wiring Termination Type | Terminal Block, Pressure Clamp, 20AWG-6AWG | |||||
Total Harmonic Distortion at Rated Power | < 2 % | |||||
Protection Devices | ||||||
Input | ||||||
Reverse Polarity Protection | Yes | Yes | ||||
Over-Voltage Protection Type | Varistor, 2 for each channel | |||||
PV Array Ground Fault Detection | Meets UL1741/NEC 690.5 requirements | |||||
PV Array Isolation Control | GFDI (for use with either Positive or negative Grounded Arrays) | |||||
Output | ||||||
Anti-Islanding Protection | Meets UL 1741/IEE1547 requirements | |||||
Over-Voltage Protection Type | Varistor, 2 (L1- L2 / L1- G) | |||||
Maximum AC OCPD Rating | 15 A | 15 A | ||||
Efficiency | ||||||
Maximum Efficiency | 96.6% | 96.6% | ||||
CEC Efficiency | 95.5% | 95.5% | 95.5% | 95.5% | 96% | 96% |
Operating Performance | ||||||
Stand-by Consumption | < 8 | |||||
Night time Consumption | < 0.6 | |||||
Communication | ||||||
User Interface | 5.5" x 1.25" graphic display | |||||
Remote Monitoring | Aurora-Universal (opt) | |||||
Wired Local Monitoring | PVI-USB-RS485_232(opt), PVI-Desktop (opt) | |||||
Wireless Local Monitoring | PVI-Desktop (opt) with PVI-Radiomodule (opt) | |||||
Environmental | ||||||
Ambient Air Operating Temperature Range | -13 to +140°F (-25/+60°C) with automatoc derating above 122°F (50°C) | -13 to +140°F (-25/+60°C) with derating above 113°F (45°C) | ||||
Ambient Air Storage Temperature Range | -40 to 176°F (-40 to +80°C) | |||||
Relative Humidity | 0-100 condensing | |||||
Acoustic Noise Emission Level | < 50 db | |||||
Maximum Operating Altitude without Derating | 6560 ft (2000m) | |||||
Mechanical Specifications | ||||||
Enclosure rating | NEMA 4X | |||||
Cooling | Natural Convection | |||||
Dimensions (H x W x D) | 30.3 x 14.4 x 6.3 inches (769 x 367 x 161 mm) with switch | |||||
Weight | < 42.5 lb (19.3 kg) with switch | |||||
Mounting System | Wall Bracket | |||||
Conduit Connections | Bottom: (2) 3/4” EKO , (3) 1/2” EKO / Left and Right Side: (1) 3/4” EKO / Back: (4) 3/4” EKO | |||||
DC Switch Rating (Per Contact) | 16 A / 600 V | |||||
Safety | ||||||
Isolation Level | High-Frequency Transformer | |||||
Safety and EMC Standard | UL 1741(2010), IEE 1547. CSA - C22.2 N. 107.1-01 FCC Part 15 Class B | |||||
Warranty | ||||||
Standard Warranty | 10 years | |||||
Extended Warranty | 15 & 20 years | |||||
Standard | UNO-2.0-I-OUTD-US | UNO-2.5-I-OUTD-US | ||||
With DC Switch & Wiring Box | UNO-2.0-I-OUTD-S-US | UNO-2.5-I-OUTD-S-US |