Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter


The Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter is no longer available from Infinigi.

Regrettably, we do not have any inventory left nor have access to this product as it is discontinued. Please note that we place this message on products that we have exhausted our options in obtaining. Contacting us will only reaffirm this message.

Thank you,
Infinigi Staff


Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter

PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter

This isolated inverter is optimized for use in residential applications requiring PV array grounding, such as some thin-fi lm modules. This inverter has also been designed to serve all countries and regions with specifi c fi eld-confi gurable set-ups available for all major country grid codes and display languages.

The 3.8/4.6kw inverters have all the usual Aurora benefi ts including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for realtime power tracking and energy harvesting, as well as regular high performance effi ciencies of up to 96.9%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.

Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

Features of the Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter:

  • Single Phase 208/240/277 Vac
  • Night Wake up button to access energy harvesting data and error log
  • Dual input section to process two strings with independent MPPT, optimize energy harvesting from multiple arrays oriented in different directions
  • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
  • High effi ciencies deliver more energy. Flat effi ciency curves to ensure consistent and stable performance across the whole input voltage and output power range
  • Anti-Islanding Protection
  • Watertight NEMA 4X (IP65) enclosure
  • Integrated DC switch in compliance with US Standards (-S Versions)
  • RS-485 communication interface (for connection to laptop or datalogger)
  • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

Also Known As:
PVI.4.6.I.OUTD.US
PVI 4.6 I OUTD US
PVI_4.6_I_OUTD_US
PVI4.6IOUTDUS

SPECIFICATIONSPVI-3.8-I-OUTD-US
PVI-3.8-I-OUTD-S-US
PVI-4.6-I-OUTD-US
PVI-4.6_I-OUTD-S-US
INPUT PARAMETERS (DC Side)
Rated DC Power4000 W4380 W
Rated Input Voltage330 V
Operating Input Voltage Range0.7 x Vstart - 520 V(1)
Activation Voltage "Vstart"  200 V (adj. 120-350 V)
Max Absolute Input Voltage (Input OV Threshold)520 V
Number of Independent MPPT Channels2
No. of DC Inputs2 pairs (Standard Version) or 1 pairs (-S Version) for each MPPT
Max. DC Rated Current for Each Input DC Connector20.0 A
Maximum DC Current, each MPPT12.5 A14.0 A
Max. Input Power, each MPPT2600 W3000 W
Input Voltage Range for Power Operation
with Parallel Confi guration of MPPT
160 - 470 V170 - 470 V
DC ConnectionsScrew Terminal Block
3 Knock-Outs: ¾" or 1" (w/ ring red.)
INPUT PROTECTION
Reverse Polarity ProtectionYes
Maximum DC Overcurrent Protection15.6 A17.0 A
DC Side Varistor4 (2 for each MPPT)
Allawable Array Ground ReferenceYes
PV Array Isolation ControlGFDI(2) (for use with either Positive or Negative Grounded Arrays)
DC Switch (-S Suffi x Version Only)600 V / 25 A
SPECIFICATIONSVI-3.8-I-OUTD-US
PVI-3.8-I-OUTD-S-US
PVI-4.6-I-OUTD-US
PVI-4.6_I-OUTD-S-US
OUTPUT PARAMETERS208 V240 V277 V208 V240 V277 V
AC Grid ConnectionSingle Phase / Split PhaseSingle Phase / Split Phase
Rated AC Power3300 W3800 W4600 W
Maximum AC Power3300W3800 W4200 V5000 W5000 W5000 W
Rated AC Voltage208 V240 V277 V208 V240 V277 V
Maximum AC Voltage Range183-228 V211-264 V244-304 V183-228 V211-264 V244-304 V
Rated AC Frequency60 Hz60 Hz
Maximum AC Line Current16.0 A16.0 A16.0 A22.5 A20.0 A20.0 A
Power Factor> 0.99
AC Current Distorsion (THD)< 2%
AC ConnectionScrew Terminal Block 3 Knock-Outs: ¾" or 1" (w/ ring red.) 2 (L - N / L - PE)
OUTPUT PROTECTION
AC Side Varistor2 (L - N / L - PE)
Maximum AC Overcurrent Protection20.0 A20.0 A20.0 A30.0 A25.0 A25.0 A
Anti Islanding ProtectionAccording to UL 1741/IEE1547
CONVERSION EFFICIENCY
Maximum Efficiency96.90%96.90%
CEC Efficiency96.00%96.50%96.50%96.00%96.50%96.50%
ENVIRONMENTAL PARAMETERS
CoolingNatural Cooling
Ambient Temperature Range-25/+60°C (-13/+ 140°F) with derating above 45°C (113°F)
Operating Altitude6000 ft
Acustical Noise< 50 dB
Environmental Protection RatingNEMA 4X (IP65)
Relative Humidity< 100% Condensing
MECHANICAL
Dimensions (H x W x D)25.2" x 12.8" x 8.3"
34.6" x 12.8" x 8.3" (-S Version)
Weight53 lb
61 lb (-S Version)
OTHERS
Stand -By Consuption< 8W
Feed In Power Threshold24.0 W
Night Time Consumption< 0.3 w
Isolation LevelHF Transformer
DisplayAlphanumeric -2 Lines
CommunicationRS 485;
Wireless (Optional, AURORA® PVI-RADIOMODULE for communication with AURORA® PVI-DESKTOP)
AVAILABLE PRODUCT VARIANTS
Standard - No OptionsPVI-3.8-I-OUTD-USPVI-4.6-I-OUTD-US
With DC SwitchPVI-3.8-I-OUTD-S-USPVI-4.6-I-OUTD-S-US
STANDARD & CODESUL 1741, IEEE 1547, CSA - C22.2 N. 107.1-01

Important note for the Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter

Shipping Note: Due to the delicate/oversized nature of this product, our online shipping system is not able to accurately determine the cost for shipping. You may proceed with an online order and we will contact you prior shipping this item or please Contact Us and we will work to get you the exact shipping cost.
Note: Specifications and pricing of the Power-One PVI-4.6-I-OUTD-US 4.6kW Aurora String Inverter subject to change without notice. Illustrations and descriptions of the Power-One PVI-4.6-I-OUTD-US do not claim to be complete or exhaustive.
Verified
PaypalVisaMastercardAmerican ExpressDiscover
Manufacturer Info
Power-One
Share Product
Share via E-Mail 
 Share on Facebook Share on Twitter