Power-One PVI-4.6-I-OUTD-S-US 4.6kW Aurora String Inverter with Integrated DC Switch
PVI-4.6-I-OUTD-S-US 4.6kW Aurora String Inverter with Integrated DC Switch
This isolated inverter is optimized for use in residential applications requiring PV array grounding, such as some thin-fi lm modules. This inverter has also been designed to serve all countries and regions with specifi c fi eld-confi gurable set-ups available for all major country grid codes and display languages.
The 3.8/4.6kw inverters have all the usual Aurora benefi ts including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for realtime power tracking and energy harvesting, as well as regular high performance effi ciencies of up to 96.9%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features of the Power-One PVI-4.6-I-OUTD-S-US 4.6kW Aurora String Inverter with Integrated DC Switch:
Also Known As:
PVI.4.6.I.OUTD.S.US
PVI 4.6 I OUTD S US
PVI_4.6_I_OUTD_S_US
PVI4.6IOUTDSUS
SPECIFICATIONS | PVI-3.8-I-OUTD-US PVI-3.8-I-OUTD-S-US | PVI-4.6-I-OUTD-US PVI-4.6_I-OUTD-S-US | |
INPUT PARAMETERS (DC Side) | |||
Rated DC Power | 4000 W | 4380 W | |
Rated Input Voltage | 330 V | ||
Operating Input Voltage Range | 0.7 x Vstart - 520 V(1) | ||
Activation Voltage "Vstart" | 200 V (adj. 120-350 V) | ||
Max Absolute Input Voltage (Input OV Threshold) | 520 V | ||
Number of Independent MPPT Channels | 2 | ||
No. of DC Inputs | 2 pairs (Standard Version) or 1 pairs (-S Version) for each MPPT | ||
Max. DC Rated Current for Each Input DC Connector | 20.0 A | ||
Maximum DC Current, each MPPT | 12.5 A | 14.0 A | |
Max. Input Power, each MPPT | 2600 W | 3000 W | |
Input Voltage Range for Power Operation with Parallel Confi guration of MPPT | 160 - 470 V | 170 - 470 V | |
DC Connections | Screw Terminal Block 3 Knock-Outs: ¾" or 1" (w/ ring red.) | ||
INPUT PROTECTION | |||
Reverse Polarity Protection | Yes | ||
Maximum DC Overcurrent Protection | 15.6 A | 17.0 A | |
DC Side Varistor | 4 (2 for each MPPT) | ||
Allawable Array Ground Reference | Yes | ||
PV Array Isolation Control | GFDI(2) (for use with either Positive or Negative Grounded Arrays) | ||
DC Switch (-S Suffi x Version Only) | 600 V / 25 A |
SPECIFICATIONS | VI-3.8-I-OUTD-US PVI-3.8-I-OUTD-S-US | PVI-4.6-I-OUTD-US PVI-4.6_I-OUTD-S-US | ||||
OUTPUT PARAMETERS | 208 V | 240 V | 277 V | 208 V | 240 V | 277 V |
AC Grid Connection | Single Phase / Split Phase | Single Phase / Split Phase | ||||
Rated AC Power | 3300 W | 3800 W | 4600 W | |||
Maximum AC Power | 3300W | 3800 W | 4200 V | 5000 W | 5000 W | 5000 W |
Rated AC Voltage | 208 V | 240 V | 277 V | 208 V | 240 V | 277 V |
Maximum AC Voltage Range | 183-228 V | 211-264 V | 244-304 V | 183-228 V | 211-264 V | 244-304 V |
Rated AC Frequency | 60 Hz | 60 Hz | ||||
Maximum AC Line Current | 16.0 A | 16.0 A | 16.0 A | 22.5 A | 20.0 A | 20.0 A |
Power Factor | > 0.99 | |||||
AC Current Distorsion (THD) | < 2% | |||||
AC Connection | Screw Terminal Block 3 Knock-Outs: ¾" or 1" (w/ ring red.) 2 (L - N / L - PE) | |||||
OUTPUT PROTECTION | ||||||
AC Side Varistor | 2 (L - N / L - PE) | |||||
Maximum AC Overcurrent Protection | 20.0 A | 20.0 A | 20.0 A | 30.0 A | 25.0 A | 25.0 A |
Anti Islanding Protection | According to UL 1741/IEE1547 | |||||
CONVERSION EFFICIENCY | ||||||
Maximum Efficiency | 96.90% | 96.90% | ||||
CEC Efficiency | 96.00% | 96.50% | 96.50% | 96.00% | 96.50% | 96.50% |
ENVIRONMENTAL PARAMETERS | ||||||
Cooling | Natural Cooling | |||||
Ambient Temperature Range | -25/+60°C (-13/+ 140°F) with derating above 45°C (113°F) | |||||
Operating Altitude | 6000 ft | |||||
Acustical Noise | < 50 dB | |||||
Environmental Protection Rating | NEMA 4X (IP65) | |||||
Relative Humidity | < 100% Condensing | |||||
MECHANICAL | ||||||
Dimensions (H x W x D) | 25.2" x 12.8" x 8.3" 34.6" x 12.8" x 8.3" (-S Version) | |||||
Weight | 53 lb 61 lb (-S Version) | |||||
OTHERS | ||||||
Stand -By Consuption | < 8W | |||||
Feed In Power Threshold | 24.0 W | |||||
Night Time Consumption | < 0.3 w | |||||
Isolation Level | HF Transformer | |||||
Display | Alphanumeric -2 Lines | |||||
Communication | RS 485; Wireless (Optional, AURORA® PVI-RADIOMODULE for communication with AURORA® PVI-DESKTOP) | |||||
AVAILABLE PRODUCT VARIANTS | ||||||
Standard - No Options | PVI-3.8-I-OUTD-US | PVI-4.6-I-OUTD-US | ||||
With DC Switch | PVI-3.8-I-OUTD-S-US | PVI-4.6-I-OUTD-S-US | ||||
STANDARD & CODES | UL 1741, IEEE 1547, CSA - C22.2 N. 107.1-01 |