Power-One PVI-4.2-OUTD-US-W 4.2kW 600VDC-208/244/277V Aurora Wind Inverter
Power-One PVI-4.2-OUTD-US-W 4.2kW 600VDC-208/244/277V Aurora String Inverter
Power-One PVI-4.2-OUTD-US-W 4.2kW 600VDC-208/244/277V Aurora Wind Inverter
Aurora grid-tie transformerless wind inverters offer a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind. The competitive initial acquisition costs matched with the high efficiencies of up to 96.9% significantly increase return on investment on wind-power installations. This compact, weather-sealed inverter has a programmable 16-point profile which allows a tight match for any compatible permanent magnet turbine.
Features of the Power-One PVI-4.2-OUTD-US-W 4.2kW 600VDC-208/244/277V Aurora Wind Inverter
Also Known As:
PVI.4.2.OUTD.US.W
PVI 4.2 OUTD US W
PVI_4.2_OUTD_US_W
PVI4.2OUTDUSW
Specifications | PVI-4.2-OUTD-US-W |
Input Parameters (DC Side) | |
Max. Input Voltage [V] | 600V |
Operating DC Input Range (Vdcmin...Vdcmax) | Operating DC Input Range (Vdcmin...Vdcmax) |
DC Input range at full power (Vfp,min...Vfp,max) | 220...530 V |
DC Power Limitation | Linear Derating From MAX to Null [530V≤Vdc≤580V] |
Maximum DC Input Current (Idcmax) | 32 A |
Max. Input Short Circuit Current | 40 A |
DC Connections Type | Screw terminal block 3 Knock-Outs: 1 ½” or 1” (w/ Ring Red.) |
Input Protection | |
Reverse Polarity Protection | No |
Input Over Voltage Protection - Varistor | 4 |
Generator Isolation Control | yes |
Output Side | 208 | 240 | 277 |
AC Grid Connection | single phase / splite phase | ||
Max. AC Power [kW] | 4200W | ||
Maximum AC Output Power (Pacmax) | 4200W | 4600W | 4600W |
Rated Grid AC Voltage (Vac,r) | 208V | 240V | 277V |
AC Voltage Range | 183-228V | 211-264V | 244-304V |
Maximum Output AC Current (Iac,max) | 20A | 20A | 20A |
Rated Frequency (fr) | 60 Hz | ||
Frequency Range (fmin...fmax) | 59.3...60.5 Hz | ||
Nominal Power Factor (Cosphiac,r) | > 0.995 | ||
Total Harmonic Distortion | < 2% | ||
AC Connections Type | Screw Terminal Block 3 Knock-Outs: 1 ½” or 1” (w/ring reducer) | ||
Output Protection | 208 | 240 | 277 |
Anti-Islanding Protection | According to UL 1741/IEE1547 | ||
Maximum AC Overcurrent Protection | 20A | 25A | 25A |
Output Over Voltage Protection - Varistor | 2 (L-N/L-PE) | ||
Operating Performance | |||
Maximum Efficiency (ηmax) | 96.8% | ||
Stand-by Consumption | < 8W | ||
Communication | |||
Wired Local Monitoring | PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) | ||
Remote Monitoring | PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) | ||
Wireless Local Monitoring | PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) | ||
User Interface | 16 characters x 2 lines LCD display | ||
Environmental | |||
Ambient Temperature Range | -25...+ 60°C/-13...140°F with derating above 55°C/131°F | ||
Noise Emission | < 50 dB(A) | ||
Maximum Operating Altitude with Derating | 2000 m / 6560 ft | ||
Physical | |||
Environmental Protection Rating | NEMA 4X | ||
Cooling | Natural | ||
Dimension (H x W x D) | 618mm x 325mm x 222mm / 24.3” x 12.8” x 8.7” | ||
Weight | 18 kg / 39.6 lb | ||
Safety | |||
Isolation Level | Transformerless | ||
Marking | cCSAus | ||
Safety and EMC standard | UL 1741, CSA - C22.2 N. 107.1-01 | ||
Grid Standard | IEEE 1547 |