Power-One PVI-4.2-OUTD-US-A 4.2kW Aurora Transformerless Inverters
PVI-4.2-OUTD-US-A 4.2 kW Single-Phase Transformerless Inverter with Dual MPPT & AFCI
The most common residential inverter is the ideal size for an averagesized family home. This family of single-phase string inverter complements the typical number of rooftop solar panels, allowing home-owners to get the most efficient energy harvesting for the size of the property. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two different orientations (ie East and West). The high speed MPPT offers real-time power tracking and improved energy harvesting. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Features of the Power-One PVI-4.2-OUTD-US-A 4.2kW Aurora Transformerless Inverters:
Also Known As:
PVI.4.2.OUTD.US.A
PVI 4.2 OUTD US A
PVI_4.2_OUTD_US_A
PVI4.2OUTDUSA
Technical Data | PVI-4.2-OUTD-US-A | ||
Nominal Output Power | 4200 W | ||
Rated Grid AC Voltage | 4200 W | 4600 W | 4600 W |
Rated Grid AC Voltage | 208 V | 240 V | 277 V |
Number of Independent MPPT Channels | 2 | ||
Maximum Usable Power for each Channel | 3000 W | ||
Absolute Maximum Voltage (Vmax) | 600 V | ||
Start-Up Voltage (Vstart) | 200 V (adj. 120-350) | ||
Full Power MMPT Voltage Range | 140-530 V | ||
Operating MMPT Voltage Range | 0.7xVstart - 580 V | ||
Maximum Current (Idcmax) for both MPPT in Parallel | 32 A | ||
Maximum Usable current per Channel | 16 A | ||
Maximum Short Circuit Current Limit per Channel | 20 A | ||
Number of Landing Terminal Per Channel | 2 Pairs | ||
Array Wiring Termination | Terminal Block, Pressure Clamp, AWG10-AWG4 | ||
Output Side (AC) | |||
Grid Connection Type | 1Ø/2W | Split-Ø/3W | 1Ø/2W |
Adjustable Voltage Range(Vmin-vmax) | 183-228V | 211-264V | 244-304V |
Grid Frequency | 60 Hz | ||
Adjustable Grid Frequency Range | 57 - 60.5 Hz | ||
Maximum Current (lacmax) | 20 | 20 | 20 |
Power Factor | > 0.995 | ||
Grid Wiring Termination Type | Terminal Block, Pressure Clamp, AWG10-AWG4 | ||
Total Harmonic Distortion at Rated Power | < 2 % | ||
Protection Devices | |||
Input | |||
Reverse Polarity Protection | Yes | ||
Over-Voltage Protection Type | Varistor, 2 for each channel | ||
PV Array Ground Fault Detection | Pre start-up Riso and dynamic GFDI (Requires Floating Arrays) | ||
Output | |||
Anti-Islanding Protection | Meets UL 1741/IEE1547 requirements | ||
Over-Voltage Protection Type | Varistor, 2 (L1- L2 / L1- G) | ||
Maximum AC OCPD Rating | 25 A | 25 A | 25 A |
Efficiency | |||
Maximum Efficiency | 97% | ||
CEC Efficiency | 96% | ||
Operating Performance | |||
Stand-by Consumption | < 8 | ||
Night time Consumption | < 0.6 | ||
Communication | |||
User Interface | 16 characters x 2 lines LCD display | ||
Remote Monitoring | Aurora-Universal (opt) | ||
Wired Local Monitoring | PVI-USB-RS485_232(opt), PVI-Desktop (opt) | ||
Wireless Local Monitoring | PVI-Desktop (opt) with PVI-Radiomodule (opt) | ||
Environmental | |||
Ambient Air Operating Temperature Range | -13/+ 140°F (-25/+60°C) | ||
Ambient Air Storage Temperature Range | -40 to 176°F (-40 to +80°C) | ||
Relative Humidity | 0-100 condensing | ||
Acoustic Noise Emission Level | < 50 db | ||
Maximum Operating Altitude without Derating | 6560 ft (2000m) | ||
Mechanical Specifications | |||
Enclosure rating | NEMA 4X | ||
Cooling | Natural Convection | ||
Dimensions (H x W x D) | 33.8 x 12.8 x 8.7 inches (859 x 325 x 222 mm) | ||
Weight | < 47.3 lb (21.3 kg) | ||
Shipping Weight | < 60 lb (27 kg) | ||
Mounting System | Wall Bracket | ||
Conduit Connections | Trade Size Kos: (2ea x 1/2”) and (2ea x 1-1/4”, 3 places side, front, rear) Side: (2) plugged 3/4” openings, (2) Concentric EKOs 3/4”, 1” Back: (4) Concentric EKOs 3/4”, 1” | ||
DC Switch Rating (Per Contact) | 25 A / 600 V | ||
Safety | |||
Isolation Level | Transformerless (Floating Array) | ||
Safety and EMC Standard | UL 1741, CSA - C22.2 N. 107.1-01 | ||
Warranty | |||
Standard Warranty | 10 years | ||
Extended Warranty | 15 & 20 years | ||
Standard- Without DC Switch and Wiring Box | PVI-4.2-OUTD-US | ||
With DC Switch and Wiring Box | PVI-4.2-OUTD-S-US | ||
With DC Switch, Wiring box and Arc Fault Detector and Interrupter | PVI-4.2-OUTD-S-US-A |