Power-One PVI-10.0-I-OUTD-US-480-NG 10kW Aurora String Inverter with Negative Ground

PVI-10.0-I-OUTD-S-US-480-NG 10kW Aurora String Inverter with Integrated DC Switch

AURORA is an inverter with the capability to supply the grid with energy obtained from photovoltaic panels. The photovoltaic panels transform the energy irradiated by the sun into electricity of the direct current 'DC' type (through a photovoltaic field, also called a PV generator); however, to use the electricity, it must be transformed into the alternating current 'AC' type. This conversion, known as DC-AC inversion, is achieved efficiently by AURORA without the use of rotating elements but only with static electronic devices. When used in parallel with the network, the alternating current output from the inverter flows directly into the domestic or industrial distribution circuit, connected in turn to the public distribution network. The solar energy system can thus feed all the connected user electrical loads. If the energy supply from the photovoltaic system is lower than the user's load requirement, the quantity of energy necessary to guarantee normal functioning of the connected appliances is taken from the public distribution network. However, when the opposite occurs, i.e. an excess of energy is produced, it is directly sent into the public network, thus becoming available to other users. In compliance with local and national regulations, the energy produced can be sold to the distribution network or credited against future consumption, thus producing energy savings.

Features of the Power-One PVI-10.0-I-OUTD-US-480-NG 10kW Aurora String Inverter with Negative Ground:

  • Standard - Negative Ground
  • Electrolyte-free’ power converter to further increase the life expectancy and long term reliability
  • True 3-phase bridge topology for DC/AC output converter
  • Night Wake up button to access energy harvesting data and error log
  • Dual input sections with independent MPP tracking, allow optimal energy harvesting from two subarrays oriented in different directions
  • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
  • Flat effi ciency curves ensure high effi ciency at all output levels insuring consistent and stable performance across the entire input voltage and output power range
  • Anti-Islanding Protection
  • Watertight NEMA 4X enclosure
  • Integrated disconnect in compliance with NA Standards (-S and -S2 Versions)
  • RS-485 communication interface (for connection to laptop or datalogger)
  • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

Also Known As:
PVI.10.0.I.OUTD.US.480.NG
PVI 10.0 I OUTD US 480 NG
PVI_10.0_I_OUTD_US_480_NG
PVI10.0IOUTDUS480NG

Parameter PVI-10.0-I-OUTD-US-208 PVI-10.0-I-OUTD-US-480 PVI-10.0-I-OUTD-CAN-600

Input Side
Start-up Input Voltage (Vdcstart) adj. 120...350 V adj. 120...350 V adj. 120...350 V
Operating Input Range (Vdcmin...Vdcmax) 0.7 x Vdcstart...520 V 0.7 x Vdcstart...520 V 0.7 x Vdcstart...520 V
MPP Input range (Vmppmax,f-Vmppmin,f) at full power 220...470 V 220...470 V 220...470 V
Input Voltage Range for Full Power Operationwith Parallel Configuration of MPPT 220...470 V 220...470 V 220...470 V
Input Voltage Range for Full Power Operationwith Independent Configuration of MPPT 270...470 V (@6500W) /
 170...470 V (@4000W)
270...470 V (@6500W) /
170...470 V (@4000W)
270...470 V (@6500W) /
170...470 V (@4000W)
Absolute Maximum Input Voltage Vmax,abs 520 V 520 V 520 V
Number of Independent MPPT 2 2 2
Maximum Input Current (Idcmax) 24.0 A 24.0 A 24.0 A
Number of DC Inputs Pairs 2 (3 on -S2 version) for each MPPT 2 (3 on -S2 version) for each MPPT 2 (3 on -S2 version) for each MPPT

Input Protection
Reverse Polarity protection Yes
Input Short Circuit Current 29.0 A
Input Side Varistors 4 (2 for each MPPT)
Photovoltaic Array Isolation Control GFDI
DC Switch 600 V / 32 A

Output Side
AC Grid Connection (Vacmin...Vacmax) Three Phases Three Phases Three Phases
Rated Power (Pac,r) 10,000 W 10,000 W 10,000 W
Power at 45°C/113°F 10,000 W 9,600 W 10,000 W
Power at 60°C/140°F 7,250 W 8,960 W 9,600 W
Rated Grid Voltage (Vac,r) 208 Vac 480 Vac 600 Vac
AC Voltage Range 183...228 V 422...528 V 544...660 V
Maximum Output Current (Iac,max) 30.0 A 14.0 A 10.6 A
Rated Frequency (fr) 60 Hz
Nominal Power Factor > 0.99
Total Harmonic Distortion < 2%

Output Protection
Anti-islanding protection According to UL 1741
Maximum AC Overcurrent Protection 35.0 A 20.0 A 20.0 A
AC Side Varistors 3 plus gas arrester
Night Time Disconnect Yes

Operating Performance
Maximum Efficiency (ηmax) 96.5 % 97.3 % 97.3 %
Weighted Efficiency (EURO/CEC) - / 96.0 % - / 97.0 % - / 97.0 %
Feed In Power Threshold 30 W
Stand-by Consumption < 8 W
Night-time power loss < 0.3 W

Communication
Monitoring System (PC/Data logger) RS485/232 (opt.), Aurora Desktop (opt.)
Remote Control RS 485, Wireless (opt.)
User Interface 16 characters x 2 lines LCD display
Environmental
Ambient Temperature Range -25...+60°C /-13...140°F with derating above 40°C/104°F -25...+60°C /-13...140°F with derating above 50°C/122°F -25...+60°C /-13...140°F with derating above 45°C/113°F
Relative Humidity < 100 % condensing
Noise Emission < 50 db(A)
Operating Altitude 2000 m / 6560 ft
Physical
Environmental Protection Rating NEMA 4X
Cooling Natural
Dimension (H x W x D) 716mm x 645mm x 208mm / 28.2” x 25.4” x 8.2”
 958 mm x 645mm x 222m / 37.7”x12.8”x8.7” (-S/-S2)
Weight 45.8 kg / 99.0 lb
 48.5 kg / 107 lb (-S Version)
51.7 / 114 lb (-S2 Version)
Mounting System Bracket support
Warranty 10 std up to 15/20 years opt.

Safety
Isolation Level HF transformer
Marking cCSAus
Safety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01
Grid Standard IEEE 1547

Available Products Variants
Standard - Positive Ground PVI-10.0-I-OUTD-US-208-PG PVI-10.0-I-OUTD-US-480-PG PVI-10.0-I-OUTD-CAN-600-PG
Standard - Negative Ground PVI-10.0-I-OUTD-US-208-NG PVI-10.0-I-OUTD-US-480-NG PVI-10.0-I-OUTD-CAN-600-NG
With DC Switch - Positive Ground PVI-10.0-I-OUTD-S-US-208-PG PVI-10.0-I-OUTD-S-US-480-PG PVI-10.0-I-OUTD-S-CAN-600-PG
With DC Switch - Negative Ground PVI-10.0-I-OUTD-S-US-208-NG PVI-10.0-I-OUTD-S-US-480-NG PVI-10.0-I-OUTD-S-CAN-600-NG
With AC and DC Switches - Positive Ground PVI-10.0-I-OUTD-S2-US-208-PG PVI-10.0-I-OUTD-S2-US-480-PG PVI-10.0-I-OUTD-S2-CAN-600-PG
With AC and DC Switches - Negative Ground PVI-10.0-I-OUTD-S2-US-208-NG PVI-10.0-I-OUTD-S2-US-480-NG PVI-10.0-I-OUTD-S2-CAN-600-NG

 

Important note for the Power-One PVI-10.0-I-OUTD-US-480-NG 10kW Aurora String Inverter with Negative Ground

Shipping Note: Due to the oversized nature of this product, freight is the only shipping method available. You may proceed with an order online and we will contact you prior shipping this item or please Contact Us and we will work to get you the exact shipping cost.
Note: Specifications and pricing of the Power-One PVI-10.0-I-OUTD-US-480-NG 10kW Aurora String Inverter with Negative Ground subject to change without notice. Illustrations and descriptions of the Power-One PVI-10.0-I-OUTD-US-480-NG do not claim to be complete or exhaustive.
Verified
PaypalVisaMastercardAmerican ExpressDiscover
Manufacturer Info
Power-One
Share Product
Share via E-Mail 
 Share on Facebook Share on Twitter