Outback Power VFX3048W Vented Off-Grid Inverter 3000W
VFX3048W Vented Off-Grid Inverter 3000W
VFX Vented Inverter/Chargers
The VFX series is designed for more protected installations. By utilizing an efficient active cooling design, the VFX models are available with AC output up to 3.6 kilowatts. Our tough die-cast aluminum chassis physically protects the internal components while the air intake includes an easily cleaned filter, which allows for ventilation while also keeping bugs and other debris out. All circuit boards are conformal-coated to prevent corrosion from airborne moisture in humid conditions. The DC wiring cover (DCC) protects the DC terminals and battery cables from damage.
Features of the Outback Power VFX3048W Vented Off-Grid Inverter 3000W:
Additional Off-Grid Inverter Specifications | Sealed Models | Vented Models | ||||
FX2024JT | FX2024WT | FX2348WT | VFX3024J | VFX3024W | VFX3048W | |
Nominal DC Input Voltage | 12 VDC | 24 VDC | 48 VDC | 12 VDC | 24 VDC | 48 VDC |
Continuous Power Rating at 25 degrees C | 2000 VA | 2000 VA | 2300 VA | 3000 VA | 3000 VA | 3000 VA |
AC Voltage/Frequency | 120 Vac 50 Hz | 230 Vac 60 Hz | 230 Vac 60 Hz | 120 Vac 50 Hz | 230 Vac 60 Hz | 230 Vac 60 Hz |
Continuous AC RMS Output current at 25 C | 8.7 amps AC | 8.7 amps AC | 10 amps AC | 13 amps AC | 13 amps AC | 13 amps AC |
Idle Power | Full ≈ 20 Watts Search ≈ 6 Watts | Full ≈ 20 Watts Search ≈ 6 Watts | Full ≈ 23 Watts Search ≈ 6 Watts | Full ≈ 20 Watts Search ≈ 6 Watts | Full ≈ 20 Watts Search ≈ 6 Watts | Full ≈ 23 Watts Search ≈ 6 Watts |
Typical Efficiency | 92% | 92% | 93% | 92% | 92% | 93% |
Total Harmonic distortion voltage (typical / max) | 2% / 5% | 2% / 5% | 2% / 5% | 2% / 5% | 2% / 5% | 2% / 5% |
Output Voltage Regulation | +/- 2% | +/- 2% . | +/- 2% | +/- 2% | +/- 2% | +/- 2% |
Maximum Output Current (Peak/RMS) | 70 amps AC/50 amps AC | 35 amps AC/50 amps AC | 35amps AC/25 amps AC | 70 amps AC/50 amps AC | 35 amps AC/25 amps AC | 35 amps AC/25 amps AC |
Overload Capability - Surge | 5750VA | 5750VA | 5750VA | 5750VA | 5750VA | 5750VA |
Overload Capability - 5 Second | 4800VA | 4800VA | 4800VA | 4800VA | 4800VA | 4800VA |
Overload Capability - 30 Minutes | 3100VA | 3100VA | 3100VA | 3100VA | 3100VA | 3100VA |
AC Input Current Maximium | 60 amps AC | 30 amps AC | 30 amps AC | 60 amps AC | 30 amps AC | 30 amps AC |
AC Input Voltage Range (MATE Adjustable) | 80 to 150 VAC | 160 to 300 VAC | 160 to 300 VAC | 80 to 150 VAC | 160 to 300 VAC | 160 to 300 VAC |
AC Input Frequency Range | 44.0 to 56.0 Hz | 54.0 to 66.0 Hz | 54.0 to 66.0 Hz | 54.0 to 66.0 Hz | 54.0 to 66.0 Hz | 54.0 to 66.0 Hz |
DC Input Range | 21.0 to 34.0 VDC | 21.0 to 34.0 VDC | 42.0 to 68.0 VDC | 10.5 to 17.0 VDC | 21.0 to 34.0 VDC | 28.0 to 45.3 VDC |
Continuous Battery Charger Output | 55 amps DC | 55 amps DC | 35 amps DC | 85 amps DC | 85 amps DC | 45 amps DC |
Operating Temperature Range | -40º C to 60º C (power derated above 25º C) | -40º C to 60º C (power derated above 25º C) | ||||
Warranty | Standard 2 year / Optional 5 year | Standard 2 year / Optional 5 year | ||||
Certifications | ETL listed to UL458 | ETL listed to UL458 | ||||
Unit Weight | 62 lbs (25 kg) | 61 lbs (25 kg) | ||||
Shipping Weight | 67 lbs (30 kg) | 67 lbs (30 kg) | ||||
Unit Dimensions (H x W x L) | 13 x 8.25 x 16.25" (33 x 21 x 41 cm) | 12 x 8.25 x 16.25" (30 x 21 x 41 cm) | ||||
Shipping Dimensions (H x W x L) | 21.75 x 13 x 22" (55 x 33 x 56 cm) | 21.75 x 13 x 22" (55 x 33 x 56 cm) |