Morningstar SS10L-12 SunSaver 10 Charge Controller with LVD
SS10L-12 SunSaver 10 Charge Controller w/LVD, 12V,10 Amp
Morningstar is pleased to introduce our third generation SunSaver. Since its first market introduction in 1996, over 1 million SunSaver controllers have been installed in over 73 countries for numerous solar power systems including oil/gas, telecom and instrumentation, marine and boating, and remote homes. We have retained much of our legacy design including the same ratings, footprint and simple user interface, and have added several new and advanced high value features:
|
|
|
|
|
|
|
|
|
Also Known As:
SS10L.12
SS10L 12
SS10L_12
SS10L12
Sunsaver (Gen3) Specifications | ||
Electrical | ||
Peak Efficiency | 97 .50% | |
System Voltage | 12 or 24 volts | |
Min. Battery Voltage | 1volt | |
Regulation voltage | 12 volt | 24 volt |
Sealed battery | 14.1 V | 28.2 V |
Flooded battery | 14.4 V | 28.8 V |
Load disconnect | 11.5 V | 23.0 V |
LVD reconnect | 12.6 V | 25.2 V |
Max. Solar Voltage | ||
12V battery | 30 volts | |
24V battery | 60 volts | |
Load in-rush capability | ||
SunSaver-6 | 45 amps | |
SunSaver-10 | 65 amps | |
SunSaver-20 | 140 amps | |
Self-consumption | < 8 mA | |
Voltage accuracy | 12V: +/– 25 mV (typical) 24V: +/– 48 mV (typical) | |
Transient surge protection | 1500W per connection | |
Mechanical | ||
Wire Size | 5 mm2 / #10 AWG | |
Weight (unpacked) | 0.23kg / 8 oz. | |
Dimensions | 15.2 x 5.5 x 3.4 cm 6.0 x 2.2 x 1.3 inch | |
Environmental | ||
Ambient Temperature | –40°C to +60°C | |
Storage Temperature | –55°C to +80°C | |
Humidity | 100% non-condensing | |
Tropicalization | Epoxy encapsulation Marine rated terminals Anodized aluminum case | |
Electronic Protections | ||
Solar: | Overload, short-circuit, high voltage | |
Load: | Overload, short-circuit, high voltage | |
Battery: | High voltage | |
All: | Reverse polarity, high temperature, lightning and transient surges | |
Battery Charging | ||
Charging method | 4 stage series PWM | |
Charging stages | Bulk, absorption, float, equalize | |
Temperature compensation | ||
Coefficient | 12V: –30mV/°C 24V: –60mV/°C | |
Range | –30°C to +60°C | |
Set Points | Absorption, float, equalize | |
LED Indications | ||
Status LED (1) | Charging or not charging Solar error conditions | |
Battery LED’s (3) | Battery level Charging stage | |
Certifications | ETL Listed to UL 1741 and CSA C22.2 No. 107.1-01 | |
Hazardous Locations | Class 1, Division 2, Groups A,B,C,D CSA C22.2#213 | |
EMC Directives | Immunity, emissions, safety | |
FCC | Class B Part 15 |