Magnum Energy ME-BMK-NS Battery Monitoring Kit - NO DC SHUNT
ME-BMK-NS Battery Monitoring Kit, NO DC SHUNT - Battery State of Charge Meter
The ME-BMK-NS (Battery Monitor Kit)* from Magnum Energy gives you a "fuel gauge" type of meter for your battery bank. It monitors the battery bank and reports the percentage state of charge, real time amps, voltage, amp-hours in/out, and the minimum/maximum DC volts.
Monitoring your battery bank is easy with the Battery Monitor Kit (ME-BMK)* from Magnum Energy. Acting as a "fuel gauge" for your batteries, the ME-BMK monitors their state of charge (SOC) and then provides this information in an easy-to-understand display via the ME-RC remote. With accurate SOC readings, you can avoid unneccessary battery recharging, saving on fuel and long-term maintenance costs. If you already have a Magnum Inverter/Charger and Magnum Remote*, the ME-BMK is an easy retrofit. Simply install the kit according to the installation manual and begin monitoring your battery bank via the "Meter" button on your ME-RC.
* The ME-BMK-NS requires a Magnum inverter with a "Network" port and a ME-RC (revision 2.0 or higher) or ME-ARC remote control.
Model Number
Available for
Works With
Available readings from the ME-BMK
The Magnum Energy ME-BMK-NS Battery Monitoring Kit - NO DC SHUNT Includes:
Also Known As:
ME.BMK.NS
ME BMK NS
ME_BMK_NS
MEBMKNS
Specifications | ME-BMK-NS |
DC volts | 7 to 70 (±0.5%) auto voltage detection |
DC amps | ±0.1 to 999 (±1.0%) |
Battery SOC % | 0 to 100% (1% increments) |
Power draw | < .6 watts |
Amp hours in/out | ±32,768 amp hours (1 AH increments) |
rAH out (resettable amp hours removed) | 0 to 65,353 amp hours, resettable (0.1 AH increments) |
tAH out (total amp hours removed) | 0 to 65,535,000 amp hours (0.1 k or 100 AH increments) |
Minimum/maximim DC | 7 to 70 VDC, resettable |
Shipping weight | 2 lb (.9 kg) |
Kit includes | Manual, sense module, DC shunt, twisted pair wire, and communication cable |
Sense wire | Twisted pair —blue & orange, 5' length, 18 AWG wire |
Communication cable | 2-conductor, 10' twisted pair, telephone standard |
Remote requirements | Use with an ME-RC with firmware revision of 2.0 or higher |