Enphase Energy ET1RC-G2-06 AC Single Drop Trunk Cable for D380 Inverter - 240 or 208 VAC
ET1RC-G2-06 AC Single Drop Trunk Cable for D380 Inverter - 240 or 208 VAC
AC Trunk cable is required to connect the Enphase D380 Inverters in the same branch. End cap installed on the last cable connector of AC Trunck cable. The Enphase ET3C-G2-06 trunk cable is used for 208 or 240 VAC single drop installations.
This table provides detailed information on the possible branch configurations and the number of end-caps and single-drop cables that would be needed.
Number of D380's | Number of Modules | Single Drop Cable | Three Drop Cable | End Caps |
1 | 2 | 1 | 0 | 0 |
2 | 4 | 0 | 1 | 2 |
3 | 6 | 0 | 1 | 1 |
4 | 8 | 1 | 1 | 0 |
5 | 10 | 0 | 2 | 2 |
6 | 12 | 0 | 2 | 1 |
7 | 14 | 1 | 2 | 0 |
8 | 16 | 0 | 3 | 2 |
9 | 18 | 0 | 3 | 1 |
10 | 20 | 1 | 3 | 0 |
11* | 22 | 0 | 4 | 2 |
12* | 24 | 0 | 4 | 1 |
13* | 26 | 1 | 4 | 0 |
14* | 28 | 0 | 5 | 2 |
15* | 30 | 0 | 5 | 1 |
* Only applies to 208 Vac configurations.
Also Known As:
ET1RC.G2.06
ET1RC G2 06
ET1RC_G2_06
ET1RCG206