Enphase Energy D380-72-2LL-S12 Inverter - Twin Module 208VAC with H4 Connector
D380-72-2LL-S12 Inverter, Twin Module 208VAC
The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and the web-based Enlighten monitoring and analysis website.
Features of the Enphase Energy D380-72-2LL-S12 Inverter - Twin Module 208VAC with H4 Connector:
Also Known As:
D380.72.2LL.S12
D380 72 2LL S12
D380_72_2LL_S12
D380722LLS12
60 AND 72 Cell Modules | ||
The D380 "TwinPack" microinverters contain 2 independent DC inputs. The Input Data (DC) values below apply to both DC Inputs A and B individually | ||
Input Data (DC) | D380-72-2LL-S12/3 | D380-72-2LL-S12/3-NA |
Recommended input power (STC) | 230W | |
Maximum input DC voltage | 56V | |
Peak power tracking voltage | 22V — 40V | |
Min./Max. start voltage | 28V/54V | |
Max. DC short circuit current | 12A | |
Max. input current | 10A | |
Output Data (AC) | @208 Vac | @240 Vac |
Maximum output power | 380W | 380W |
Nominal output current | 1.8A | 1.6A |
Nominal voltage/range | 208V/183V-229V | 240V/211V-264V |
Extended voltage/range | 208V/179V-232V | 240V/206V-269V |
Nominal frequency/range | 60.0/59.3-60.5 | 60.0/59.3-60.5 |
Extended frequency/range | 60.0/59.2-60.6 | 60.0/59.2-60.6 |
Power factor | >0.95 | >0.95 |
Maximum units per 20A branch | 15 | 10 |
Peak inverter efficiency | 95.5% | |
CEC weighted efficiency | 95.0% | |
Nominal MPP tracking | 99.6% | |
Mechanical Data | ||
Operating temperature range | -40ºC to +65ºC | |
Night time power consumption | 50mW | |
Dimensions (WxHxD) | 12.25" x 6.00" x 1.33" | |
Weight | 6.25 lbs | |
Cooling | Natural Convection — No Fans | |
Enclosure environmental rating | Outdoor — NEMA 6 | |
Features | ||
Communication | Powerline | |
Warranty | 15 Years | |
Compliance | UL1741/IEEE1547, FCC Part 15 Class B |