C60 Charge Controller, 60A, 12/24/48V
Xantrex
C Series- Small System Charge or Lighting or Load Controller
Features
» The C Series offers three models, the C35, C40, and C60, that can handle 35,40, and 60 amps of DC current.
» Silent, pulse width modulated (PWM), high efficiency operation.
» Three-stage battery charging (bulk, absorption, and float).
» Automatic overload protection in both active and passive modes.
» PV array short circuit and reverse polarity protection.
» Durable construction.
» Backed by a two year warranty.
» Microprocessor controlled.
As a Solar Charge Controller
» When used as a solar charge controller, the C40 can control 12, 24, or 48 VDC array operation and the C35 and C60 can control 12 and 24 VDC array operation.
» All units offer selectable settings for NiCad, flooded lead acid, gel, or absorbed glass mat batteries.
As a DC Load Controller
» As a DC load controller, the C Series has a low voltage disconnect warning system and field adjustable set points that govern automatic low and high voltage disconnect.
» Manual reset switch for emergency low voltage operation.
As a Diversion Load Controller
» The C Series automatically directs extra power to a dedicated load such as an electric water heater and ensures batteries are never over-charged.
Options
» Plug-in remote temperature sensor (BTS) for increased charging precision.
» Cumulative amp-hour meter (CM) that can be installed on the face of the controller, or remotely (CM/R), up to 100 feet (30 m) away.
| Electrical Specifications |
| Voltage Configurations | 12 and 24 VDC |
| Max. PV Open Circuit Array Voltage | 55 VDC |
| Charging / Load Current (at 25 °C) | 60 amps DC |
| Max. Peak current | 85 amps |
| Max. Voltage Drop through Controller | 0.30 volts |
| Typical Operating Consumption | 15 ma |
| Typical Idle Consumption | 3 ma |
| Recommended Breaker Size | 60 amps rated at 1000% continuous duty |
| Recommended Wire Size | #6 AWG rated at 90 °C |
| Lead AcidBatterySettings | Adjustable |
| NiCadBatterySettings | Adjustable |
| Load Control Mode | Low Voltage Reconnect - Adjustable (sticker provided with unit) all models |
| | Low Voltage Disconnect - User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selectable grace period) all models |
| General Specifications for the Xantrex C60 |
| SpecifiedTemperatureRange | 32° F to 104° F (0° C to 40° C) |
| Enclosure Type | Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts |
| Unit Weight | |
| Shipping Weight | |
| Dimensions (H x W x D) | |
| Shipping Dimensions (H x W x D) | |
| Mounting | Vertical wall mount - indoor only |
| Altitude - Operating | 15,000' (4,572 m) |
| Altitude - Non-Operating | 50,000' (15,240 m) |
| Warranty | Two years |
| Part Numbers | C5, C40, C60 - Controllers |
| | CM - Front Display Panel |
| | CM/R-50, CM/R-100 - Remote Display Panel |
| | BTS -Batterytemperature sensor |
| Features & Options |
| Regulation Method | Solid stage, three-stage (bulk, absorption, and float), pulse width modulation |
| Field Adjustable Control Setpoints | Two user adjustable voltage setpoints for control of loads or charging sources - setting retained if battery is disconnected |
| Display Panel | CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50' (15 m) or 100' (30.5 m) cable |
| Equalization Charge | User selectable manual or automatic equalization - every 30 days |
| BatteryTemperature Sensor | BTS - optional remote battery temperature sensor for increased charging precision |
| Regulatory Approvals | UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant |