XP125 Sinewave Inverter 125W, 12V
EXELTECH
XP 125 Power Inverter
Made in America, EXELTECH XP SERIES INVERTERS are the most affordable, reliable, lightweight and best regulated, true sine wave inverters available. The XP SERIES inverter will operate any AC load anywhere. Ultra lightweight, yet rugged enough for the most extreme mobile enviroments, the XP SERIES is available in 100Vac, 120Vac, or 230Vac in 50Hz, 60Hz or 400Hz for land, marine or military applications, worldwide.
Features
- True Sine Wave
- 125 Watts to 1100 Watts
- 12 Vdc to 108 Vdc Input
- Rack Mount Optional
- Remote Switching
- 21.5 Years MTBF
Output Power
Continuous Power | Surge Power | No Load Power | Output Voltage | Output Current | Weight LBS. | 125 Watt | 150 Watts | 5 Watts | 100 +/- 6% | 1.2 | 2 | 125 Watt | 150 Watts | 5 Watts | 120 +/- 6% | 1.1 | 2 | 250 Watt** | 300 Watts | 6 Watts | 100 +/- 6% | 2.5 | 5 | 250 Watt** | 300 Watts | 6 Watts | 120 +/- 6% | 2.1 | 5 | 250 Watt** | 300 Watts | 7 Watts | 230 +/- 6% | 1.1 | 5 | 600 Watt** | 1100 Watts | 8 Watts | 100 +/- 6% | 6.0 | 6.5 | 600 Watt** | 1100 Watts | 8 Watts | 120 +/- 6% | 5.1 | 6.5 | 600 Watt** | 1100 Watts | 9 Watts | 230 +/- 6% | 2.7 | 6.5 | 1100 Watt** | 2200 Watts | 20 Watts* | 100 +/- 6% | 11.0 | 10 | 1100 Watt** | 2200 Watts | 20 Watts* | 120 +/- 6% | 9.5 | 10 | 1100 Watt** | 2200 Watts | 20 Watts* | 230 +/- 6% | 4.8 | 10 | *10W with X2 option **remote switchable |
Input PowerModel Voltage | Minimum (Typical)** | System (Typical) | Maximum (Typical)** | Typical Efficiency @ Full Power | Peak Efficiency @ 1/3 Power | 12Vdc | 10.4/10.6Vdc* | 13.8Vdc | 16.5Vdc | 85% | 87% | 24Vdc | 19/21Vdc* | 27.6Vdc | 33Vdc | 87% | 89% | 32Vdc | 26.5/28Vdc* | 36.8Vdc | 44Vdc | 88% | 90% | 48Vdc | 41.5/42.1Vdc* | 55.2Vdc | 62Vdc | 87% | 89% | 66Vdc | 57.5/58.5Vdc* | 75.9Vdc | 91.1Vdc | 88% | 90% | 108Vdc | 94/95Vdc* | 125Vdc | 149Vdc | 87% | 90% |
|
| *Indicates typical cut-off voltage/warning buzzer voltage ** +/- 3% |
General
Conditions | Minimum | Typical | Maximum | Waveform | - | Sinusoidal | - | Voltage Output | - 5% | Nominal | +5% | Line Regulation | - | 0.1% | 0.5% | Load Regulation | - | 0.5% | 1% | Distortion | - | 1.5% | 2% | Frequency | -0.1% | Nominal | +0.1% |
|
| Mechanical |
Protection CicuitryOver Voltage*:Shut off at maximum input voltage, per input conditions. Automatic reset upon fault correction. Under Voltage*:Shut off at minimum input voltage, per input conditions Thermal*:105 C internal temperature. Warning buzz 5 C before shut off Output Short:Unit shuts off (manual reset) | *Automatically reset |
EnvironmentalTemperature:-25 to 30 C full power derated above 30 C. Derate 20% per 10 C. Humidity:5 to 95% non condensing Altitude:-200 to 10k feet full power, derated above 10k Audible Noise:Less than 45dbA Cooling:600W/1100W Thermo- statically controlled forced air. 125W/250W convection cooled. Finish:Painted aluminum Warranty:Full year parts laborView the >Limited Warranty |
|