Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC


The Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC is no longer available from Infinigi.

Regrettably, we do not have any inventory left nor have access to this product as it is discontinued. Please note that we place this message on products that we have exhausted our options in obtaining. Contacting us will only reaffirm this message.

Thank you,
Infinigi Staff


Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC

 ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC

AC Trunk cable is required to connect the Enphase D380 Inverters in the same branch.  End cap installed on the last cable connector of AC Trunck cable. The Enphase ET3R-G2-06 green label trunk cable is used for 208 or 240 Vac single phase.

Features of the Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC

D380 TwinPack Trunk Cable
The D380 TwinPack cable assembly is constructed with a 12 gauge trunk cable and three "drop" cables at the inverter locations. The drop cables are spaced at two module-wide intervals. TwinPack cable assemblies are connected end to end to create a branch circuit of the desired length. Dimensions of the cable assembly are shown below in inches.

  

The 12 gauge trunk cable would be protected with a 20 amp circuit breaker allowing up to 33% more power per branch circuit, compared to branch circuits of the M190 and M210. A single 20 amp branch circuit would allow for up to 10 D380 TwinPack microinverters (20 PV modules) at 240 Vac, or 15 D380 TwinPack microinverters (30 PV modules) at 208 Vac. Different models of trunk cable are used depending on whether the installation is 240 Vac or 208Vac.

  • ET3R-G2-06 green label trunk cable is used for 208 or 240 Vac single phase
  • ET3C-G2-06 blue label trunk cable is used for 208 three phase installations.

 

Installation
The D380 TwinPack cable assembly has been designed with 3 inverter tap cables spaced at 2 module wide intervals. Twinpack cable assemblies would be connected end to end to create a branch circuit of the desired length. The twinpack cable assembly is then fastened to the module racking. D380 twinpack microinverters mount to the module racking below one of the associated PV modules.

For PV modules installed in landscape orientation, the D380 twinpack microinverters could be mounted to the vertical module supports. The spacing between inverter taps is intended for 2 rows of PV modules.

    This table provides detailed information on the possible branch configurations and the number of end-caps and single-drop cables that would be needed.

    Number of
    D380's
    Number of
    Modules
    Single Drop
    Cable
    Three Drop
    Cable 
    End Caps
    1  2 1 0 0
    2 4 0 1 2
    3 6 0 1 1
    4 8 1 1 0
    5 10 0 2 2
    6 12 0 2 1
    7 14 1 2 0
    8 16 0 3 2
    9 18 0 3 1
    10 20 1 3 0
    11*  22 0 4 2
    12*  24 0 4 1
    13*  26 1 4 0
    14*  28 0 5 2
    15*  30 0 5 1

    * Only applies to 208 Vac configurations.

    Also Known As:
    ET3R.G2.06
    ET3R G2 06
    ET3R_G2_06
    ET3RG206

    Note: Specifications and pricing of the Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC subject to change without notice. Illustrations and descriptions of the Enphase Energy ET3R-G2-06 do not claim to be complete or exhaustive.

    Customers Who Bought the Enphase Energy ET3R-G2-06 AC Trunk Cable with 3 Drops for D380 Inverter - 240 VAC Also Purchased:

    Verified
    PaypalVisaMastercardAmerican ExpressDiscover
    Manufacturer Info
    Enphase Energy
    Share Product
    Share via E-Mail 
     Share on Facebook Share on Twitter