| SPECIFICATIONS | Solar Boost 6024H |
| Output Current Rating | 60 Amp Maximum |
| Nominal Battery Voltage | 12 / 24VDC Field Selectable |
| Nominal PV Voltage | 36VDC / 48VDC (3 or 4 series modules) Field Selectable |
| PV Open Circuit Voltage | 140VDC Maximum |
| Standby Power Consumption | 30mA Typical |
| Charge On Power Consumption | 190 / 120mA @ 12 / 24VDC (with fan operating) |
| Charge Algorithm | 3 stage charge. Acceptance/Float transition based on charge current matched to battery amp-hours. Can accept external shunt signal for optimal charge control with widely varying loads. Selectable for 2 stage charge. |
| Acceptance Voltage Setpoint | 13-16VDC / 26-32VDC |
| Float Voltage Setpoint | 0-2VDC / 0-4VDC< Acceptance |
| Equalization Voltage | Acceptance + 1.0 / 2.0VDC |
| Voltage Step-down | Cannot operate as conventional 12VDC or 24VDC charge controller, must operate in high voltage input / low voltage output step-down mode |
| Temperature Compensation | Optional temperature sensor adjusts charge voltage setpoint based on measured battery temperature. Field selectable slope, -5.0mV/°C/cell (lead-acid), or -2.0mV/°C/cell (NiCd) |
| Power Conversion Efficiency | 95% @ 28 Volt 50 Amp Output |
| Cabinet Dimensions | 10"H x 8¾"W x 3½"D (25.5cm x 22.6cm x 8.74cm) |
| Digital Display | Available in the unit, as a remote, or both. Shows PV input current, output charge current, battery voltage, charge mode and state of charge. Remote display mounts in standard duplex box, includes 25 foot (7.6m) cable. Maximum cable length to 300 feet (91.4m). |
| Digital Display Range/Accuracy | Voltmeter, 70.0VDC / ±0.30% F.S. Ammeter, 60.0A / ±0.50% F.S. |
| Specified Temperature Range | 0 to +40°C (Extended range -40 to +60°C, will operate but may not meet spec. - see Technical Bulletin 100206) |