8784W Solar Grid Tie System - 36 Samsung 244W, SB8000U SMA Inverter, and Mounts
The Samsung 8784W Residential Solar Grid-Tie Systems (SGTS) provide reliable power for your home or business using top quality UL listed products. Each grid tie system is pre-packaged to save design time and includes solar modules, mounting systems, inverters, cables and all necessary hardware and electrical components. The Samsung 8784W residential / business solar grid-tie system is modular which means you can combine multiple units together or add to your system in the future.
The Samsung 8784W solar grid-tie system meet NEC code requirements and US safety standards. The mounts securely attach the array to the roof in compliance with US Building Codes. Complete installation guide and operational manual included.
Features of the 8784W Solar Grid Tie System - 36 Samsung 244W, SB8000U SMA Inverter, and Mounts:
Also Known As:
SAM.8784.SB8000U.M
SAM 8784 SB8000U M
SAM_8784_SB8000U_M
SAM8784SB8000UM
Specification for Samsung Module LPC244SM-08 | |
Performance at Standard Test Conditions (STC) : Irradiance 1000 W/m2, AM 1.5, and cell temperature 25 °C | |
Maximum power Pmax | 244 W |
Maximum power voltage | 37.5 V |
Maximum power current | 8.58 A |
Open circuit voltage | 30.3 V |
Short circuit current | 8.07 A |
Module Efficency | 15.24% |
Performance at Nominal Operating Cell Temperature (NOCT) : Irradiance 800 W/m2, ambient temperature 20°C, wind speed 1m/s | |
Maximum power Pmax | 196 W |
Maximum power voltage | 37.3 V |
Maximum power current | 6.88 A |
Open circuit voltage Short circuit current | 30.4 V |
Short circuit current | 6.48 A |
System integration parameters | |
Maximum system voltage (IEC) | 1,000 VDC |
Maximum system voltage (UL) | 600 VDC |
Maximum series fuse rating | 15 A |
Safety Ratings & Warranties | |
Fire Safety Classification | Class C |
Certifications | UL 1703, CEC, IEC61215, IEC61730 |
Warranty | 5 years limited product warranty |
Performance guarantee | 10 years limited warranty of 90% power output 25 years limited warranty of 80% power output |
Qualification Test | |
Temp cycling range | -40 °C to 85 °C for 200 cycles |
Damp heat test | 85 °C and 85% relative humidity for 1000 hr |
Front load test (Snow) | 5400 Pa |
Rear static load test(Wind) | 2400 Pa |
Hailstone impact test | 25 mm hail at 23 m/s from 1 m distance |
Temperature coefficients | |
NOCT | 46 ± 2 °C |
TC Isc | -0.07% / K |
TC Voc | -0.35% / K |
TC Pmax | -0.48% / K |
(NOCT : Nominal Operating Cell Temperature) | |
Packing Configuration | |
Container | 40'HC |
Piece per pallet | 20 |
Pallets per container | 26 |
Physical Characteristics | |
Cells per module | 60 |
Cell type | Mono-crystalline Silicon |
Module dimensions | 1630 x 982 x 46 mm 64.17x 38.66 x 1.85 inches |
Front Glass | 3.2 mm (0.13 inches)Tempered glass |
Module weight | 18.6 kg (41.01 lb) |
Juntion Box | |
Connector Type | Bizlink S418-xyz series (MC4 compatible) |
IP Grade | IP65 |
Output Cable | (+) 1200mm, (-) 800mm 47.2 inches, (-) 31.5 inches |
Specification for SMA Inverter | Sunny Boy SB 5000US | Sunny Boy SB 6000US | Sunny Boy SB 7000US | Sunny Boy SB 8000US |
208 V AC 240 V AC 277 V AC | 208 V AC 240 V AC 277 V AC | 208 V AC 240 V AC 277 V AC | 240 V AC 277 V AC | |
Input (DC) | ||||
Recommended Maximum PV Power (Module STC) | 6250 W | 7500 W | 8750 W | 10000 W |
Max. DC Power | 5300 W | 6350 W | 7400 W | 8600 W |
DC Maximum Voltage | 600 V | 600 V | 600 V | 600 V |
DC Nominal Voltage | 310 V | 310 V | 310 V | 345 V |
MPP Voltage Range | 250—480 V | 250—480 V | 250—480 V | 300—480 V |
Min DC Voltage/Start Voltage | 250 V / 300 V | 250 V / 300 V | 250 V / 300 V | 300 V / 365 V |
Max. input current / per string (at DC disconnector) | 21 A/20A 36A @ combined terminal | 25 A/20A 36A @ combined terminal | 30 A/20A 36A @ combined terminal | 30 A/20A 36A @ combined terminal |
Number of MPP trackers/ fused-protected strings per MPP tracker | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) |
Output (AC) | ||||
AC Nominal Power | 5000 W | 6000 W | 7000 W | 8000 W |
AC Maximum Output Power | 5000 VA | 6000 VA | 7000 VA | 8000 VA |
AC Maximum Output Current (@ 208, 240, 277 V) | 24 A, 21 A, 18 A | 29 A, 25 A, 22 A | 34 A, 29 A, 25 A | N/A, 32 A, 29 A |
AC Voltage Range | 183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V | 183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V | 183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V | 211 — 264 V @ 240 V 244 — 305 V @ 277 V |
AC Grid Frequency; range | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz |
Power Factor (Nominal) | 1 | 1 | 1 | 1 |
Phase conductors / connection phases | 1 / 2 1 / 2 1 / 1 | 1 / 2 1 / 2 1 / 1 | 1 / 2 1 / 2 1 / 1 | 1 / 2 1 / 1 |
Harmonics | < 4 % | < 4 % | < 4 % | < 4 % |
Efficiency | ||||
Max Efficiency | 96.7% @ 208 V 96.8% @ 240 V 96.8% @ 277 V | 96.9% @ 208 V 96.8% @ 240 V 97.0% @ 277 V | 97.1% @ 208 V 96.9% @ 240 V 97.0% @ 277 V | 96.3% @ 240 V 96.5% @ 277 V |
CEC Weighted Efficiency | 95.5% @ 208 V 95.5% @ 240 V 95.5% @ 277 V | 95.5% @ 208 V 95.5% @ 240 V 96.0% @ 277 V | 95.5% @ 208 V 96.0% @ 240 V 96.0% @ 277 V | 96.0% @ 240 V 96.0% @ 277 V |
General Data | ||||
Dimensions: (W / H / D) in inches | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 |
DC Disconnect dimensions (W / H / D) in inches | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 |
Packing dimensions (W / H / D) in inches | 31 x 15 x 23 | 31 x 15 x 23 | 31 x 15 x 23 | 31 x 15 x 23 |
DC Disconnect packing dimensions (W / H / D) in inches | 23 x 16 x 11 | 23 x 16 x 11 | 23 x 16 x 11 | 23 x 16 x 11 |
Weight /DC Disconnect Weight | 148 lbs / 8 lbs | 148 lbs / 8 lbs | 148 lbs / 8 lbs | 152 lbs / 9 lbs |
Operating temperature range (full power) | —25 °C ... +45 °C / —13 °F ... +113 °F | —25 °C ... +45 °C / —13 °F ... +113 °F | —25 °C ... +45 °C / —13 °F ... +113 °F | —25 °C ... +45 °C / —13 °F ... +113 °F |
Noise emission (typical) | 44 dB(A) | 44 dB(A) | 44 dB(A) | 44 dB(A) |
Internal consumption: (night) | 0.1 W | 0.1 W | 0.1 W | 0.1 W |
Topology | LF transformer | LF transformer | LF transformer | LF transformer |
Cooling Concept | OptiCool | OptiCool | OptiCool | OptiCool |
Electronics protection rating / connection area | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R |
Features | ||||
Display: text line / graphic | yes /— | yes /— | yes /— | yes /— |
Interfaces: RS485 / Bluetooth | opt. / opt. | opt. / opt. | opt. / opt. | opt. / opt. |
Warranty: 10 years / 15 years / 20 years | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. |
Certificates and permits (more available on request) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) |
Type designation | SB 5000US | SB 6000US | SB 7000US | SB 8000US |