The Solon 5060W Residential Solar Grid-Tie Systems (SGTS) provide reliable power for your home or business using top quality UL listed products. Each grid tie system is pre-packaged to save design time and includes solar modules, mounting systems, inverters, cables and all necessary hardware and electrical components. The Solon 5060W residential / business solar grid-tie system is modular which means you can combine multiple units together or add to your system in the future.
The Solon 5060W solar grid-tie system meet NEC code requirements and US safety standards. The mounts securely attach the array to the roof in compliance with US Building Codes. Complete installation guide and operational manual included.
Features of the 5060W Solar Grid Tie System - 22 Solon 230W, SB5000US SMA Inverter, and Mounts:
Also Known As:
SOL.5060.SB5000US.M
SOL 5060 SB5000US M
SOL_5060_SB5000US_M
SOL5060SB5000USM
Specification for Solon 230W Module:
Mechanical specifications | Solon Blue P220/6+/01 230WP | |||||||
Length | 1,660 mm | |||||||
Width | 990 mm | |||||||
Height | 42 mm | |||||||
Weight | 26 kg | |||||||
Junction box diodes | A SOLON junction box with bypass | |||||||
Cable | Solar cable, length 900 mm, 4 mm2, prefabricated with MC plug | |||||||
Front glass | White toughened safety glass, 4 mm | |||||||
Cells | 60 pc. polycrystalline Si 6.2" (156 x 156 mm) | |||||||
Cell encapsulation | EVA (Ethylene-Vinyl-Acetate) | |||||||
Back | Tedlar composite film | |||||||
Frame | Anodised aluminium profile | |||||||
Dimensions of the frameless module | 1,633 x 993 x 5 mm (L x W x H) | |||||||
Electrical specifications (typical) | ||||||||
?Module class Pmax (± 3 %): | 235 Wp | 230 Wp | 225 Wp | 220 Wp | 215 Wp | 210 Wp | 205 Wp | 200 Wp |
Rated voltage Umpp: | 29,2 V | 29,0 V | 28,9 V | 28,8 V | 28,5 V | 28,3 V | 28,1 V | 27,8 V |
Rated current Impp: | 8,05 A | 7,95 A | 7,80 A | 7,65 A | 7,55 A | 7,45 A | 7,30 A | 7,20 A |
Open circuit voltage Uoc: | 36,9 V | 36,7 V | 36,6 V | 36,4 V | 36,3 V | 36,1 V | 35,9 V | 35,6 V |
Short circuit current Isc: | 8,65 V | 8,55 V | 8,40 V | 8,30 V | 8,20 V | 8,10 V | 8,00 V | 7,90 V |
Maximum system voltage: | 860 V | 860 V | 860 V | 860 V | 860 V | 860 V | 860 V | 860 V |
Module efficiency: | 14,30 % | 14,00 % | 13,69 % | 13,39 % | 13,08 % | 12,78 % | 12,47 % | 12,17 % |
Operating conditions | ||||||||
Temperature range | - 40 °C to + 85 °C | |||||||
Hail | maximum diameter of 28 mm with impact speed of 86 km/h | |||||||
Maximum surface load capacity | tested up to 5,400 Pa according to IEC 61215 (advanced test) |
Specification for SMA Inverter:
Sunny Boy SB 5000US | Sunny Boy SB 6000US | Sunny Boy SB 7000US | Sunny Boy SB 8000US | |
208 V AC 240 V AC 277 V AC | 208 V AC 240 V AC 277 V AC | 208 V AC 240 V AC 277 V AC | 240 V AC 277 V AC | |
Input (DC) | ||||
Recommended Maximum PV Power (Module STC) | 6250 W | 7500 W | 8750 W | 10000 W |
Max. DC Power | 5300 W | 6350 W | 7400 W | 8600 W |
DC Maximum Voltage | 600 V | 600 V | 600 V | 600 V |
DC Nominal Voltage | 310 V | 310 V | 310 V | 345 V |
MPP Voltage Range | 250—480 V | 250—480 V | 250—480 V | 300—480 V |
Min DC Voltage/Start Voltage | 250 V / 300 V | 250 V / 300 V | 250 V / 300 V | 300 V / 365 V |
Max. input current / per string (at DC disconnector) |
21 A/20A 36A @ combined terminal |
25 A/20A 36A @ combined terminal |
30 A/20A 36A @ combined terminal |
30 A/20A 36A @ combined terminal |
Number of MPP trackers/ fused-protected strings per MPP tracker | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) | 1 / 4 (DC disconnect) |
Output (AC) | ||||
AC Nominal Power | 5000 W | 6000 W | 7000 W | 8000 W |
AC Maximum Output Power | 5000 VA | 6000 VA | 7000 VA | 8000 VA |
AC Maximum Output Current (@ 208, 240, 277 V) | 24 A, 21 A, 18 A | 29 A, 25 A, 22 A | 34 A, 29 A, 25 A | N/A, 32 A, 29 A |
AC Voltage Range |
183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V |
183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V |
183 — 229 V @ 208 V 211 — 264 V @ 240 V 244 — 305 V @ 277 V |
211 — 264 V @ 240 V 244 — 305 V @ 277 V |
AC Grid Frequency; range | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz | 60 Hz / 59.3 — 60.5 Hz |
Power Factor (Nominal) | 1 | 1 | 1 | 1 |
Phase conductors / connection phases |
1 / 2 1 / 2 1 / 1 |
1 / 2 1 / 2 1 / 1 |
1 / 2 1 / 2 1 / 1 |
1 / 2 1 / 1 |
Harmonics | < 4 % | < 4 % | < 4 % | < 4 % |
Efficiency | ||||
Max Efficiency |
96.7% @ 208 V 96.8% @ 240 V 96.8% @ 277 V |
96.9% @ 208 V 96.8% @ 240 V 97.0% @ 277 V |
97.1% @ 208 V 96.9% @ 240 V 97.0% @ 277 V |
96.3% @ 240 V 96.5% @ 277 V |
CEC Weighted Efficiency |
95.5% @ 208 V 95.5% @ 240 V 95.5% @ 277 V |
95.5% @ 208 V 95.5% @ 240 V 96.0% @ 277 V |
95.5% @ 208 V 96.0% @ 240 V 96.0% @ 277 V |
96.0% @ 240 V 96.0% @ 277 V |
General Data | ||||
Dimensions: (W / H / D) in inches | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 | 18.4 x 24.1 x 9.5 |
DC Disconnect dimensions (W / H / D) in inches | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 | 7.3 x 11.7 x 7 |
Packing dimensions (W / H / D) in inches | 31 x 15 x 23 | 31 x 15 x 23 | 31 x 15 x 23 | 31 x 15 x 23 |
DC Disconnect packing dimensions (W / H / D) in inches | 23 x 16 x 11 | 23 x 16 x 11 | 23 x 16 x 11 | 23 x 16 x 11 |
Weight /DC Disconnect Weight | 148 lbs / 8 lbs | 148 lbs / 8 lbs | 148 lbs / 8 lbs | 152 lbs / 9 lbs |
Operating temperature range (full power) |
—25 °C ... +45 °C / —13 °F ... +113 °F |
—25 °C ... +45 °C / —13 °F ... +113 °F |
—25 °C ... +45 °C / —13 °F ... +113 °F |
—25 °C ... +45 °C / —13 °F ... +113 °F |
Noise emission (typical) | 44 dB(A) | 44 dB(A) | 44 dB(A) | 44 dB(A) |
Internal consumption: (night) | 0.1 W | 0.1 W | 0.1 W | 0.1 W |
Topology | LF transformer | LF transformer | LF transformer | LF transformer |
Cooling Concept | OptiCool | OptiCool | OptiCool | OptiCool |
Electronics protection rating / connection area | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R |
Features | ||||
Display: text line / graphic | yes /— | yes /— | yes /— | yes /— |
Interfaces: RS485 / Bluetooth | opt. / opt. | opt. / opt. | opt. / opt. | opt. / opt. |
Warranty: 10 years / 15 years / 20 years | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. |
Certificates and permits (more available on request) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B) |
Type designation | SB 5000US | SB 6000US | SB 7000US | SB 8000US |