The Trina 2925W Residential Solar Grid-Tie Systems (SGTS) provide reliable power for your home or business using top quality UL listed products. Each grid tie system is pre-packaged to save design time and includes solar modules, mounting systems, inverters, cables and all necessary hardware and electrical components. The Trina 2925W residential / business solar grid-tie system is modular which means you can combine multiple units together or add to your system in the future.
The Trina 2925W solar grid-tie system meet NEC code requirements and US safety standards. The mounts securely attach the array to the roof in compliance with US Building Codes. Complete installation guide and operational manual included.
Features of the 2925W Solar Grid Tie System - 13 Trina 225W, SB4000U SMA Inverter, and Mounts:
Also Known As:
TRI.2925.SB4000U.M
TRI 2925 SB4000U M
TRI_2925_SB4000U_M
TRI2925SB4000UM
Electrical Data @ STC | TSM-225PA05 |
Peak Power Watts-PMAX (WP) | 225 |
Power Output Tolerance-PMAX (%) | 0/+3 |
Maximum Power Voltage-VMAX (V) | 29.4 |
Maximum Power Current-IMPP (A) | 7.66 |
Open Circuit Voltage-VOC (V) | 36.9 |
Short Circuit Current-ISC (A) | 8.20 |
Encapsulated Cell Efficiency (%) | 15.4 |
Module Efficiency (%) | 13.7 |
Values at Standard Test Conditions STC (Air Mass AM1.5, Irradiance 1000W/m², Cell Temperature 25°C) | |
General Data | |
Cell Type | 6 x 6in Multicrystalline silicon, 60pcs in series |
Glass | High Transmission, Low Iron, Tempered Glass 0.13 in |
Frame | Anodized Aluminum |
Junction Box/Connector | 1. Tyco / Tyco, IP65 2. Renhe / MC4, IP65 |
Temperature Ratings | |
Nominal Operating Cell Temperature (NOCT) | 46°C (±2°C) |
Temperature Coefficient of PMPP | -0.45%/°C |
Temperature Coefficient of VOC | -0.35%/°C |
Temperature Coefficient of ISC | 0.05%/°C |
Maximum Ratings | |
Operating Temperature | -40 +85°C |
Storage Temperature | -40 +85°C |
Maximum System Voltage | 600VDC |
Maximum Series Fuse | 15A |
Mechanical and Packing Configuration | |
Dimensions | (A x B X C) 64.96 x 39.05 x 1.57in |
Installation Hole Dimensions (E x F) | 38.98 x 37.05in |
Cable length (G) | 39.37in |
Weight | 43lb |
Packing Configuration | 25 pcs/carton |
Quantity/Pallet | 1carton/pallet |
Loading Capacity | 650pcs/40ft |
Warranty | 5 years manufacturing warranty 10 years warranty, 90% power output 25 years warranty, 80% power output |
Specification for SMA Sunny Boy Inverter | Sunny Boy 3000-US | Sunny Boy 4000-US |
208 V AC 240 V AC | 208 V AC 240 V AC | |
Input (DC) | ||
Max. recommended PV power (@ module STC) | 3750 W | 4375 W 5000 W |
Max. DC power (@ cos ? = 1) | 3200 W | 4200 W |
Max. DC voltage | 500 V | 600 V |
DC nominal voltage | 250 V | 310 V |
MPP voltage range | 175 — 400 V2 200 — 400 V | 220 — 480 V 250 — 480 V |
Min. DC voltage / start voltage | 175 / 228 V 200 / 228 V | 220 / 285 V 250 / 285 V |
Max. input current / per string (at DC disconnect) | 17 A / 17 A 36 A @ combined terminal | 18 A / 18 A 36 A @ combined terminal |
Output (AC) | ||
AC nominal power | 3000 W | 3500 W 4000 W |
Max. AC apparent power | 3000 VA | 3500 VA 4000 VA |
Nominal AC voltage / adjustable | 208 V / yes 240 V / yes | 208 V / yes 240 V / yes |
AC voltage range | 183 — 229 V 211 — 264 V | 183 — 229 V 211 — 264 V |
AC grid frequency; range | 60 Hz; 59.3 — 60.5 Hz | 60 Hz; 59.3 — 60.5 Hz |
Max. output current | 15 A 13 A | 17 A |
Power factor (cos ?) | 1 | 1 |
Phase conductors / connection phases | 1 / 2 | 1 / 2 |
Harmonics | < 4% | < 4% |
Efficiency | ||
Max. efficiency | 96% 96.5% | 96.5% 96.8% |
CEC efficiency | 95% 95.5% | 95.5% 96.0% |
Protection devices | ||
DC reverse-polarity protection | yes | yes |
AC short circuit protection | yes | yes |
Galvanically isolated / all-pole sensitive monitoring unit | yes / - | yes / - |
Protection class / overvoltage category | I / III | I / III |
General Data | ||
Dimensions (W / H / D) in mm (in) | 450 / 350 / 235 (18 / 14 / 9) | 450 / 350 / 235 (18 / 14 / 9) |
DC Disconnect dimensions (W / H / D) in mm (in) | 187 / 297 / 190 (7 / 12 / 7.5) | 187 / 297 / 190 (7 / 12 / 7.5) |
Packing dimensions (W / H / D) in mm (in) | 390 / 580 / 470 (15 / 23 / 18.5) | 390 / 580 / 470 (15 / 23 / 18.5) |
DC Disconnect packing dimensions (W / H / D) in mm (in) | 370 / 240 / 280 (15 / 9 / 11) | 370 / 240 / 280 (15 / 9 / 11) |
Weight / DC Disconnect weight | 38 kg (84 lb) / 3.5 kg (8 lb) | 38 kg (84 lb) / 3.5 kg (8 lb) |
Packing weight / DC Disconnect packing weight | 44 kg (97 lb) / 4 kg (9 lb) | 44 kg (97 lb) / 4 kg (9 lb) |
Operating temperature range (full power) | —25 °C ... +45 °C (—13 °F ... +113 °F) | —25 °C ... +45 °C (—13 °F ... +113 °F) |
Noise emission (typical) | 40 dB(A) | 37 dB(A) |
Internal consumption at night | 0.1 W | 0.1 W |
Topology | LF transformer | LF transformer |
Cooling concept | OptiCool | OptiCool |
Electronics protection rating / connection area | NEMA 3R / NEMA 3R | NEMA 3R / NEMA 3R |
Features | ||
Display: text line / graphic | yes / - | yes / - |
Interfaces: RS485 / Bluetooth | opt. / opt. | opt. / opt. |
Warranty: 10 / 15 / 20 years | yes / opt. / opt. | yes / opt. / opt. |
Certificates and permits (more available on request) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B), CSA C22.2 No. 107.1-2001 | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B), CSA C22.2 No. 107.1-2001 |
Data at nominal conditions | ||
Type designation | SB 3000US | SB 4000US |